Passa al contenuto
Merck
Tutte le immagini(2)

Documenti fondamentali

GE28-9269-79

HiScreen Capto S

Cytiva 28-9269-79

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
47101511
NACRES:
NA.56

ligand

sulfonate group

Descrizione

Ion Exchanger Type (value)

Stato

prepacked column

Crosslinking

cross-linked

Confezionamento

pkg of 1 ea

Produttore/marchio commerciale

Cytiva 28-9269-79

Condizioni di stoccaggio

(0.2 M Sodium Acetate in 20% Ethanol)

Parametri

44 psi

tecniche

liquid chromatography (LC): suitable

Dimensioni del letto

7.7 mm × 100 mm

Volume del letto

4.7 mL

Diam. int. colonna

7.7 mm

Matrice

highly cross-linked agarose with dextran surface extender

Gruppo funzionale matrice

SO3- functional group

Diametro medio

90 μm (d50v)

cleaning

3-14

Intervallo di esercizio

4-13

Capacità

binding capacity(> 120 mg lysozyme/mL resin)

Compatibilità

suitable for bioprocess medium

Tecnica di separazione

cation exchange

Descrizione generale

HiScreen Capto S columns are prepacked with Capto S ion exchange chromatography medium, and are part of the process development platform available from Cytiva. The columns are an excellent choice for method optimization and parameter screening.

The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.

If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.

Media prepacked in HiScreen Capto IEX columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.

Caratteristiche e vantaggi

  • Capto S is a strong cation exchange BioProcess medium, designed to meet the demands of modern large-scale manufacturers for fast, efficient, and cost-effective capture and intermediate protein purification.
  • Prepacked, ready-to-use columns for convenient process development optimization.
  • 1NA cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
  • Easily connected in series to achieve 2NA cm bed height.
  • Small bed volume gives fast results and minimal sample/buffer consumption.
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity.

Stoccaggio e stabilità

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (0.2 M sodium acetate in 20% ethanol)
Store at 4 to 30 °C (20% Ethanol + 0.2 M Sodium Acetate)

Risultati analitici

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Note legali

Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva

Prodotti correlati

N° Catalogo
Descrizione
Determinazione del prezzo

Pittogrammi

Flame

Avvertenze

Warning

Indicazioni di pericolo

Codice della classe di stoccaggio

3 - Flammable liquids


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documenti section.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.