Passa al contenuto
Merck
Tutte le immagini(3)

Key Documents

SCT254

Sigma-Aldrich

BioTracker FQ Orange Cox-2 Live Cell Probe

Human

Sinonimo/i:

BioTracker FQ Orange Cox-2 Live Cell Probe, COX-2 live cell dye, COX-2 live cell probe, FQ live cell probe, cyclooxygenase-2 live cell dye, cyclooxygenase-2 live cell probe

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
41106514
NACRES:
NB.12

product name

BioTracker FQ Orange Cox-2 Live Cell Probe,

Origine biologica

human

Livello qualitativo

Forma fisica

lyophilized solid

Confezionamento

vial of 500 μg

Produttore/marchio commerciale

Millipore

tecniche

activity assay: suitable
cell culture | stem cell: suitable
flow cytometry: suitable

Condizioni di spedizione

dry ice

Temperatura di conservazione

−20°C

Descrizione generale

Fluorocoxib-Q (FQ) Orange is a redox-activatable probe suitable for live cell imaging of COX-2. In contrast to other COX-2 reactive compounds such as fluorocoxib-A, FQ Orange produces fluorescent signal only in a redox environment characteristic of cells with high COX-2 expression.
Active COX-2 is localized to the outer nuclear membrane and endoplasmic reticulum. The localization of FQ Orange probe signal in colorectal cancer cells is consistent with the nuclear periphery, as demonstrated by nuclear counterstaining with Hoechst.

FQ Orange has also demonstrated utility in vivo tumor imaging (2).

MW=1098.78 g/mol
Probe is soluble in DMSO.


For representative data, SCC736 Human Colorectal Organoids were incubated with 200 nM FQ probe in appropriate growth medium for 3 hours

SPECTRAL PROPERTIES

Excitation max λ: 586 nm
Emission max λ: 607 nm
Activated BioTracker FQ Orange Cox-2 Live Cell Probe is detectable using a 561 nm laser excitation and a propidium iodide/Texas Red filter.

1. Chan G et al. Cyclooxygenase-2 expression is up-regulated in squamous cell carcinoma of the head and neck. Cancer Res 59(5):991-994 (1999)
2. Uddin MJ et al. Discovery of a redox-activatable chemical probe for detection of cyclooxygenase-2 in cells and animals. ACS Chem Biol 17:1714-1722 (2022)

Applicazioni

Purity: > 98% confirmed by HNMR, LC-MS and HPLC and elemental analysis

Caratteristiche e vantaggi

This orange fluorescent probe detects cyclooxygenase-2 (COX-2)---a key enzyme associated with inflammatory processes and neoplasia---in live cells.

Descrizione del bersaglio

Cyclooxygenase-2 is an enzyme that catalyzes the formation of prostaglandin H2, a branch point in the biosynthetic pathway leading to the bioactive lipids prostaglandin, thromboxane, and prostacyclin. These compounds function in processes including inflammation, platelet aggregation, and gastric cytoprotection. COX-2 is highly regulated and its expression is induced by a wide range of cytokines, growth factors, and tumor promoters, making COX-2 a key enzyme in inflammatory responses and neoplastic tissues. For example, COX-2 is a marker for colon cancer tumorigenesis, being highly expressed in colorectal carcinoma but nearly undetectable in surrounding normal tissue. (1). The importance of COX-2 expression especially as a preneoplastic/tumorigenic marker thus highlights the need for in vivo detection reagents.

Stato fisico

Dark blue solid. Upon reconstitution, probe solution is clear.

Stoccaggio e stabilità

Store BioTracker FQ Orange Cox-2 Live Cell Probe at -20°C, desiccated and protected from lightNote: Centrifuge vial briefly to collect contents at bottom of vial before opening.

Altre note

Live cell probe for detection of COX-2 activity by fluorescence microscopy or flow cytometry. Unlike other COX-2 reactive compounds such as fluorocoxib-A, BioTracker FQ Orange Cox-2 Live Cell Probe produces fluorescent signal only in a redox environment characteristic of cells with high COX-2 expression.

Note legali

BioTracker is a trademark of Merck KGaA, Darmstadt, Germany

Esclusione di responsabilità

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Codice della classe di stoccaggio

11 - Combustible Solids

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.