KVGLG1THH1
Capsula Opticap® XLT con membrana Durapore® da 0,22 µm
Opticap® XLT 10, inlet connection diam. 5/8 in., cartridge nominal length 10 in. (25 cm)
Sinonimo/i:
Opticap Gamma Compatible XLT10 Durapore 0.22 μm 5/8 in. HB
About This Item
Materiali
PVDF
polyester support
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
silicone seal
Livello qualitativo
Conformità normativa
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Sterilità
non-sterile
Compatibilità con la sterilizzazione
gamma compatible
Nome Commerciale
Opticap® XLT 10
Caratteristiche
gamma compatible
hydrophilic
Produttore/marchio commerciale
Opticap®
Parametri
≤14 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. inlet pressure (15 psi) at 80 °C
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
tecniche
sterile filtration: suitable
Lunghezza
37.6 cm (14.8 in.)
Larghezza
7.8 in.
Lunghezza nominale della cartuccia
10 in. (25 cm)
Diametro
10.7 cm (4.2 in.)
Superficie filtrante
0.73 m2
Diam. connessione ingresso
5/8 in.
Amp. ingresso/ uscita
19.8 cm (7.8 in.)
Diam. connessione uscita
5/8 in.
Impurezze
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Estraibili (gravimetria)
≤25 mg/capsule
Matrice
Durapore®
Dimensione pori
0.22 μm
input
sample type liquid
Punto di bolla
≥3450 mbar (50 psig), air with water at 23 °C
Raccordi
1/4 in. drain/vent hose barb (with double O-ring Seal)
(16 mm (5?8 in.) Hose Barb Inlet and Outlet)
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
Descrizione generale
Confezionamento
Altre note
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Nota sulla preparazione
3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
Risultati analitici
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Note legali
Esclusione di responsabilità
Non trovi il prodotto giusto?
Prova il nostro Motore di ricerca dei prodotti.
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.