Passa al contenuto
Merck
Tutte le immagini(1)

Documenti

KHGEA10TT1

Millipore

Capsule Opticap® XL, membrana Millipore Express® SHC

Opticap® XL 10, inlet connection diam. 1-1/2 in., pore size 0.5/0.2 μm, cartridge nominal length 10 in. (25 cm)

Sinonimo/i:

Opticap Autoclavable XL 10 Millipore Express SHC 0.5/0.2 μm 1-1/2 in. TC/TC

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
23151806
eCl@ss:
32031690

Materiali

polyethersulfone membrane
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
polysulfone
silicone seal

Livello qualitativo

Conformità normativa

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Sterilità

non-sterile

Compatibilità con la sterilizzazione

autoclavable compatible

Nome Commerciale

Opticap® XL 10

Caratteristiche

hydrophilic

Produttore/marchio commerciale

Millipore Express®

Parametri

≤28.2  mL/min air diffusion at 2.8  bar (40  psig) and 23 °C ( in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

tecniche

sterile filtration: suitable

Lunghezza

33.5 cm (13.2 in.)

Larghezza

4.2 in.

Lunghezza nominale della cartuccia

10 in. (25 cm)

Diametro

10.7 cm (4.2 in.)

Superficie filtrante

0.49 m2

Diam. connessione ingresso

1-1/2 in.

Amp. ingresso/ uscita

33.5 cm (13.2 in.)

Diam. connessione uscita

1-1/2 in.

Impurezze

≤0.25 EU/mL (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Matrice

Millipore Express® SHC

pore size

0.5/0.2 μm pore size

Punto di bolla

≥4000 mbar (58 psig), air with water at 23 °C

Raccordi

1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet sanitary flange
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)

Descrizione generale

Device Configuration: Capsule

Confezionamento

Double Easy-Open bag

Altre note

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Nota sulla preparazione

Sterilization Method
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Risultati analitici

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 20 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L

Note legali

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Esclusione di responsabilità

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Not finding the right product?  

Try our Motore di ricerca dei prodotti.


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.