KGW6A2TBB1
Capsule Opticap® XLT, matrice Polysep™ II 1,0/0,5 µm nominale
pore size 1.0/0.5 μm, Opticap® XLT 20, cartridge nominal length 20 in. (50 cm)
About This Item
Materiali
borosilicate glass fiber (BGF) membrane
mixed cellulose esters (MCE) membrane
polypropylene filter
polypropylene housing
polypropylene support
silicone seal
Livello qualitativo
Conformità normativa
FDA 21CFR177-182 (all component materials)
Sterilità
non-sterile
Compatibilità con la sterilizzazione
autoclavable compatible
Nome Commerciale
Opticap® XLT 20
Caratteristiche
hydrophilic
Produttore/marchio commerciale
Opticap®
Parametri
1 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
tecniche
prefiltration: suitable
Lunghezza nominale della cartuccia
20 in. (50 cm)
device L
62.5 cm (24.6 in.)
device size
20 in.
filter filtration area
0.92 m2
Diam. connessione ingresso
1 in.
inlet to outlet width
19.8 cm (7.8 in.)
Diam. connessione uscita
1 in.
Impurezze
≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL bacterial endotoxins (LAL test, sample aqueous extraction)
Matrice
Polysep™ II
pore size
1.0/0.5 μm nominal pore size
1.0/0.5 μm pore size
Raccordi
(25 mm (1 in.) Hose Barb Inlet and Outlet)
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
Categorie correlate
Descrizione generale
Caratteristiche e vantaggi
Confezionamento
Nota sulla preparazione
3 autoclave cycles of Sterilization Method: 30min at 121°C; not in-line steam sterilizable
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21CFR210.3(b)(6).
Risultati analitici
Altre note
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer first page of Visual Inspection Guide and introduction section of Mixed cellulose esters Tech Brief
- Storage Statement: Please refer Mixed cellulose esters Tech Brief
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Note legali
Non trovi il prodotto giusto?
Prova il nostro Motore di ricerca dei prodotti.
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.