HSTCMAG384PX21BK
MILLIPLEX® 384-well Human High Sensitivity T Cell Premixed 21-Plex Panel-Space Saver (Bulk) Packaging
for the analysis of a combination of analytes in serum, plasma, or tissue/cell culture supernatant
About This Item
Prodotti consigliati
Livello qualitativo
Reattività contro le specie
human
Produttore/marchio commerciale
Milliplex®
assay range
accuracy: 79-108%
standard curve range: 0.18-750 pg/mL
(IL-6)
standard curve range: 0.24-1,000 pg/mL
(IL-13)
standard curve range: 0.24-1,000 pg/mL
(IL-21)
standard curve range: 0.31-1,250 pg/mL
(IL-8)
standard curve range: 0.31-1,250 pg/mL
(MIP-1α)
standard curve range: 0.37-1,500 pg/mL
(IL-7)
standard curve range: 0.43-1,750 pg/mL
(TNFα)
standard curve range: 0.49-2,000 pg/mL
(IL-1β)
standard curve range: 0.49-2,000 pg/mL
(IL-12 (p70))
standard curve range: 0.49-2,000 pg/mL
(IL-2)
standard curve range: 0.49-2,000 pg/mL
(IL-5)
standard curve range: 0.61-2,500 pg/mL
(IFNγ)
standard curve range: 0.61-2,500 pg/mL
(MIP-3α)
standard curve range: 0.73-3,000 pg/mL
(IL-17A)
standard curve range: 0.92-3,750 pg/mL
(MIP-1β)
standard curve range: 1.22-5,000 pg/mL
(GM-CSF)
standard curve range: 1.46-6,000 pg/mL
(IL-10)
standard curve range: 1.46-6,000 pg/mL
(ITAC)
standard curve range: 1.83-7,500 pg/mL
(IL-4)
standard curve range: 18.3-75,000 pg/mL
(Fractalkine)
standard curve range: 7.93-32,500 pg/mL
(IL-23)
inter-assay cv: <20%
intra-assay cv: <10%
tecniche
multiplexing: suitable
Compatibilità
configured for Premixed
Metodo di rivelazione
fluorometric (Luminex xMAP)
Condizioni di spedizione
ambient
Categorie correlate
Descrizione generale
Low levels of inflammation are involved in many clinical and sub-clinical disease states, such as autoimmune disease, cardiovascular disease, diabetes, neurological disorders, and cancer. Measuring picogram levels of cytokines, therefore, is critical for understanding the pathogenesis of these diseases.
The 384-well Human High Sensitivity T Cell Panel is the 384-well version of the current 96-well Human High Sensitivity T Cell Panel, and it exceeds expectations in terms of throughput, sensitivity and sample detectability.
The MILLIPLEX® 384-well Human High Sensitivity T Cell Premixed 21-Plex Panel is to be used for the simultaneous quantification of these analytes in serum, plasma, or tissue/cell culture supernatant: Fractalkine/CX3CL1, GM-CSF, IFN-γ, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8/CXCL8, IL-10, IL-12 (p70), IL-13, IL-17A/CTLA8, IL-21, IL-23, ITAC/EXCL11, MIP-1α/CCL3, MIP-1β/CCL4, MIP-3α/CCL20 and TNFα.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Cytokines/Chemokines
Specificità
There is no detectable cross-reactivity within the panel.
Applicazioni
- Analytes: Fractalkine, GM-CSF, IFNγ, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-10, IL-12 (p70), IL-13, IL-17A, IL-21, IL-23, I-TAC, MIP-1α, MIP-1β, MIP-3α, TNF-α
- Because there are unique features concerning sample prep and assay set-up, please read the entire protocol before running the assay.
- Recommended Sample type: Serum, plasma or tissue/cell lysate and culture supernatant
- Assay Run Time: Overnight
- Research Category: Inflammation & Immunology
- Research Subcategory: Immune Response, Metabolic Disorders, Chronic Inflammatory Disease, Cardiovascular Disease, Neuroscience
Stoccaggio e stabilità
Altre note
Note legali
Esclusione di responsabilità
Avvertenze
Danger
Indicazioni di pericolo
Classi di pericolo
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Organi bersaglio
Respiratory Tract
Codice della classe di stoccaggio
10 - Combustible liquids
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.