GCYT1-16K
MILLIPLEX® Chicken Cytokine/Chemokine Panel 1 - Immunology Multiplex Assay
About This Item
Reattività contro le specie
chicken
Produttore/marchio commerciale
Milliplex®
assay range
accuracy: 87-100%
(using the overnight protocol)
accuracy: 95-100%
(using the 2 hour protocol)
standard curve range: 12.21-20,000 pg/mL
(for RANTES)
standard curve range: 122.1-500,000 pg/mL
(for IL-6)
standard curve range: 18.3-75,000 pg/mL
(for IFNγ)
standard curve range: 18.3-75,000 pg/mL
(for MIP-3α)
standard curve range: 24.4-100,000 pg/mL
(for IL-10)
standard curve range: 3.66-15,000 pg/mL
(for IFNα)
standard curve range: 36.6-150,000 pg/mL
(for IL-21)
standard curve range: 4.88-20,000 pg/mL
(for MIP-1β)
standard curve range: 4.88-20,000 pg/mL
(for VEGF)
standard curve range: 48.8-200,000 pg/mL
(for IL-2)
standard curve range: 7.32-30,000 pg/mL
(for IL-16)
standard curve range: 9.75-40,000 pg/mL
(for M-CSF)
inter-assay cv: <20%
intra-assay cv: <10%
tecniche
multiplexing: suitable
Metodo di rivelazione
fluorometric (Luminex® xMAP®)
Condizioni di spedizione
wet ice
Temperatura di conservazione
2-8°C
Categorie correlate
Descrizione generale
EMD Millipore′s MILLIPLEX® Chicken Cytokine/Chemokine Panel is a 12-plex kit to be used for the simultaneous quantification of any or all of the following analytes in chicken serum, plasma and PBMC samples: Interferon alpha (IFNα), Interferon gamma (IFNγ), Interleukin 2 (IL-2), Interleukin 6 (IL-6), Interleukin 10 (IL-10), Interleukin 16 (IL-16), Interleukin 21 (IL-21), Macrophage Inflammatory protein-1β (MIP-1b), Macrophage Inflammatory protein-3 (MIP-3a), RANTES (regulated on activation, normal T cell expressed and secreted), Macrophage colony-stimulating factor (M-CSF), Vascular endothelial growth factor (VEGF).
Note: The protocol recommends a 1:4 dilution of serum and plasma samples.
MILLIPLEX® offers the broadest selection of analytes across a wide range of disease states and species. Once the analytes of interest have been identified, you can rely on the quality that we build into each kit to produce results you can trust. In addition to the assay characteristics listed in the protocol, other performance criteria evaluated during the verification process include: cross-reactivity, dilution linearity, kit stability, and sample behavior (e.g. detectability and stability). In addition each panel and kit meets stringent manufacturing criteria to ensure batch-to-batch reproducibility.
Each MILLIPLEX® panel and kit includes:
- Quality controls (QCs) to qualify assay performance
- Comparison of standard (calibrator) and QC lots to a reference lot to ensure lot-to-lot consistency
- Optimized serum matrix to mimic native analyte environment in serum and plasma samples
- Detection antibody cocktails designed to yield consistent analyte profiles within panel
The MILLIPLEX® Chicken Cytokine/Chemokine Panel thus enables you to focus on the therapeutic potential of cytokines and chemokines.
Specificità
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Applicazioni
- This assay may be run overnight (16-18 hours) at 2-8°C or for 2 hours at room temperature (20-25°C) with agitation on a plate shaker.
- A maximum of 25 μL per well 1:4 serum or plasma diluted in Serum Matrix should be used for all analytes. Tissue culture supernatants may require dilution in appropriate control medium. Tissue/cell extracts should be prepared in neutral buffers containing reagents and conditions that do not interfere with assay performance.
Analytes Available:
- IL-16
- IFN-α
- IFNγ
- IL-10
- IL-21
- IL-2
- M-CSF
- IL-6
- MIP-3α
- MIP-1β
- RANTES
- VEGF
Research Category:
- Inflammation & Immunology
Research Sub-Category:
- Inflammation & Autoimmune Mechanisms
- Inflammation
- Infectious Diseases
- Cytokines & Cytokine Receptors
- Oncology
- Obesity
- Metabolic Disorders
Caratteristiche e vantaggi
Confezionamento
Risultati analitici
Note legali
Avvertenze
Danger
Indicazioni di pericolo
Classi di pericolo
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Organi bersaglio
Respiratory Tract
Codice della classe di stoccaggio
10 - Combustible liquids
Classe di pericolosità dell'acqua (WGK)
WGK 3
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Contenuto correlato
Learn the benefits of using biomarker detection multiplex immunoassays for laboratory, companion, and agricultural animal research and explore MILLIPLEX® multiplex assays for veterinary medicine and animal health research.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.