CTGB03TP3
Cartucce Aerex®, 0,2 µm
pore size 0.2 μm, cartridge nominal length 30 in. (75 cm), Code 0 (2-222; O-rings)
Sinonimo/i:
Aerex CTGB Cartridge Filter 30 in. 0.2 µm Code 0
About This Item
Materiali
PTFE
polypropylene
polypropylene support
silicone seal
Livello qualitativo
Sterilità
non-sterile
Compatibilità con la sterilizzazione
steam-in-place compatible
Nome Commerciale
Aerex®
Caratteristiche
hydrophobic
Produttore/marchio commerciale
Aerex®
Parametri
≤45 mL/min nitrogen diffusion at 690 mbar (10 psig) and 23 °C (in 60/40% IPA/water)
0.35 bar max. differential pressure (5 psid) at 145 °C (Forward)
0.35 bar max. inlet pressure (5 psi) at 145 °C (Forward)
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (Forward)
5.2 bar max. differential pressure (75 psid) at 25 °C (Reverse; intermittent)
5.2 bar max. inlet pressure (75 psi) at 25 °C (Reverse)
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward)
7 bar max. inlet pressure (100 psi) at 25 °C (Forward)
tecniche
gas filtration: suitable
Lunghezza
30 in.
Larghezza
2.7 in.
Lunghezza nominale della cartuccia
30 in. (75 cm)
Diametro
6.9 cm (2.7 in.)
Superficie filtrante
1.95 m2
Impurezze
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Estraibili (gravimetria)
≤105 mg/cartridge
Matrice
Aerex®
Dimensione pori
0.2 μm pore size
input
sample type gas
Punto di bolla
≥900 mbar (13 psig), nitrogen with 60/40% IPA/water at 23 °C
Codice cartuccia
Code 0 (2-222; O-rings)
Descrizione generale
Caratteristiche e vantaggi
Confezionamento
Altre note
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Qualità
Nota sulla preparazione
200 (150 forward/50 reverse) SIP cycles of 30 min @ 145 °C; SIP up to 165 hours in forward direction @ 145 °C
Risultati analitici
Note legali
Non trovi il prodotto giusto?
Prova il nostro Motore di ricerca dei prodotti.
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.