1.05718
TLC plates, Cellulose F
pkg of 25 plates, plate L × W 20 cm × 20 cm, glass support
Sinonimo/i:
Cellulose Coated TLC Plates
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Codice UNSPSC:
41115711
NACRES:
NB.21
Prodotti consigliati
Materiali
cellulose matrix
glass support
Livello qualitativo
Caratteristiche
binder Organic Polymer
fluorescent indicator
Confezionamento
pkg of 25 plates
tecniche
thin layer chromatography (TLC): suitable
Spessore strato
80-120 μm
Lungh. × largh. lastra
20 cm × 20 cm
Temperatura di conservazione
2-30°C
Descrizione generale
25 Glass plates 20 x 20 cm
Our cellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid derivatives. We offer cellulose plates in two grades: TLC for conventional and HPTLC for demanding, high-performance separations.
Applicazioni
- HPTLC/DESI-MS imaging of tryptic protein digests separated in two dimensions.: This study by Pasilis et al. explores the use of High-Performance Thin-Layer Chromatography (HPTLC) combined with Desorption Electrospray Ionization Mass Spectrometry (DESI-MS) for imaging tryptic protein digests. The application of cellulose F TLC plates was crucial in separating protein fragments, providing high-resolution and accurate mass spectrometry analysis. This method showcases the versatility and efficiency of cellulose F TLC plates in advanced proteomics research (Pasilis et al., 2008).
Linkage
Replaces: 5718-7; 5718
Risultati analitici
Layer thickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
Aminoacid test
hRf-values
- L-serine, amino acid test:
20 - 30
- L-threonine, amino acid test: 29 - 36
- L-alanine, amino acid test: 30 - 40
- L-methionine, amino acid test: 49 - 60
- L-phenylalanine, amino acid test: 59 - 70
- L-leucine, amino acid test: 66 - 76
Typical value determined on a plate
Eluent: 1-Butanol/ acetone/ acetic acid/ water (35/35/7/23 v/v/v/v) twice developed
Deviation of layer thickness per plate: ≤ 30 µm
Aminoacid test
hRf-values
- L-serine, amino acid test:
20 - 30
- L-threonine, amino acid test: 29 - 36
- L-alanine, amino acid test: 30 - 40
- L-methionine, amino acid test: 49 - 60
- L-phenylalanine, amino acid test: 59 - 70
- L-leucine, amino acid test: 66 - 76
Typical value determined on a plate
Eluent: 1-Butanol/ acetone/ acetic acid/ water (35/35/7/23 v/v/v/v) twice developed
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.