1.05636
HPTLC plates, Silica gel 60 DIOL F₂₅₄s
pkg of 25 plates, plate L × W 20 cm × 10 cm, glass support
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Materiali
glass support
silica gel 60 matrix
Livello qualitativo
Caratteristiche
binder Organic Polymer
fluorescent indicator
Confezionamento
pkg of 25 plates
tecniche
HPTLC: suitable
Spessore strato
200 μm
Lungh. × largh. lastra
20 cm × 10 cm
Dimensione particelle
5-6 μm
Dimensione pori
60 Å medium pore diameter
Temperatura di conservazione
2-30°C
Descrizione generale
25 Glass plates 20 x 10 cm
Our NH2, CN and DIOL -modified silica sorbents are less polar then conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH2 plates provide weak basic ion exchange characteristics with special selectivity for charged compounds.
Risultati analitici
Specific surface area (according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testings:
A) Steroidtest, straight phase
hRf-values
- hydrocortisone, straight phase:
4 - 8
- Reichstein S, straight phase: 11 - 18
- Methyltestosterone, straight phase: 27 - 36
B) Steroid test, reversed phase
- methyltestosterone, steroid test: 48 - 68
- Reichstein S, steroid test: 58 - 78
- hydrocortisone, steroid test: 68 - 88
Typical value determined on an activated plate (120°C, 15 min)
Eluent a) petroleum benzine 40-60°/acetone (80/20 v/v)
Eluent b) acetone/water (30/70 v/v)
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testings:
A) Steroidtest, straight phase
hRf-values
- hydrocortisone, straight phase:
4 - 8
- Reichstein S, straight phase: 11 - 18
- Methyltestosterone, straight phase: 27 - 36
B) Steroid test, reversed phase
- methyltestosterone, steroid test: 48 - 68
- Reichstein S, steroid test: 58 - 78
- hydrocortisone, steroid test: 68 - 88
Typical value determined on an activated plate (120°C, 15 min)
Eluent a) petroleum benzine 40-60°/acetone (80/20 v/v)
Eluent b) acetone/water (30/70 v/v)
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.