F-017

Supelco

(±)-Flecainide solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula empirica (notazione di Hill):
C17H20F6N2O3
Numero CAS:
Peso molecolare:
414.34
Numero CE:
Numero MDL:
Codice UNSPSC:
41116107
ID PubChem:
NACRES:
NA.24

Grado

certified reference material

Livello qualitativo

Stato

liquid

Caratteristiche

Snap-N-Spike®/Snap-N-Shoot®

Confezionamento

ampule of 1 mL

Produttore/marchio commerciale

Cerilliant®

Concentrazione

1.0 mg/mL in methanol

tecniche

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

applicazioni

clinical testing

Formato

single component solution

Temperatura di conservazione

−20°C

Stringa SMILE

O=C(NCC1CCCCN1)C2=CC(OCC(F)(F)F)=CC=C2OCC(F)(F)F

InChI

1S/C17H20F6N2O3/c18-16(19,20)9-27-12-4-5-14(28-10-17(21,22)23)13(7-12)15(26)25-8-11-3-1-2-6-24-11/h4-5,7,11,24H,1-3,6,8-10H2,(H,25,26)
DJBNUMBKLMJRSA-UHFFFAOYSA-N

Informazioni sul gene

human ... SCN5A(6331)

Descrizione generale

Flecainide, marketed under trade names such as Almarytm, Apocard, Ecrinal®, and Flécaine, is a class Ic antiarrhythmic drug used to prevent and treat a variety of cardiac arrhythmias. This Certified Spiking Solution® is suitable for use as a starting material in the preparation of calibrators, controls, or linearity standards in flecainide therapeutic drug monitoring methods by LC/MS or LC that ensure patients remain within the drug′s narrow therapeutic range.

Note legali

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Ecrinal is a registered trademark of Laboratoires Asepta Corporation Monaco
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

Organi bersaglio

Eyes,Central nervous system

Codice della classe di stoccaggio

3 - Flammable liquids

Classe di pericolosità dell'acqua (WGK)

WGK 2

Punto d’infiammabilità (°F)

49.5 °F - closed cup

Punto d’infiammabilità (°C)

9.7 °C - closed cup


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Ci dispiace, ma al momento non ci sono COA disponibili online per questo prodotto.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Heather Ellsworth et al.
Pacing and clinical electrophysiology : PACE, 36(3), e87-e89 (2012-08-14)
Flecainide is a Vaughan Williams Class Ic antidysrhythmic associated with PR, QRS, and QTc prolongation on the electrocardiogram and development of life-threatening cardiac toxicity in overdose. The cornerstone of treatment is fluid resuscitation and the administration of magnesium and sodium
[Flecainide intoxication].
Santiago Nogué et al.
Medicina clinica, 140(1), 46-46 (2012-10-03)
Joseph J Lynch et al.
Journal of cardiovascular pharmacology, 61(3), 226-232 (2012-11-29)
This study explored the intrinsic vasorelaxant and inotropic effects of the mixed potassium and sodium channel blocker atrial antiarrhythmic vernakalant and the class IC antiarrhythmic agent flecainide in human isolated subcutaneous resistance artery and in ventricular trabecular muscle preparations. At
Antiarrhythmic drug treatment after cardioversion of atrial fibrillation.
Marcelle D Smit et al.
Lancet (London, England), 380(9852), 1467-1467 (2012-10-30)
ECG diagnosis: flecainide toxicity.
Joel T Levis
The Permanente journal, 16(4), 53-53 (2012-12-20)

Articoli

For efficient therapeutic drug monitoring, it is important for clinicians to have access to fast and robust analytical methods for accurate assessment of drug efficacy. Industrial trends toward highly specific LC/MS applications over traditional immunoassay have resulted in the need for high-speed chromatographic assays along with simplified sample preparation methods.

The benefit of HILIC over traditional reversed-phase chromatography is two-fold for both sample introduction and analyte detection. First, the high acetonitrile concentration of HILIC mobile phases allows for direct analysis of precipitated plasma samples without the need for additional sample solvent exchange. Second, the high acetonitrile content provides increased analyte response in positive ESI MS detection.

Contenuto correlato

HILIC mobile phases consist of a high composition of acetonitrile, which facilitates the direct analysis of precipitated plasma samples without the need for additional sample solvent exchange.

Chromatograms

application for HPLCapplication for HPLC

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.