76492
10,12-Pentacosadiynoic acid
≥97% (HPLC)
Sinonimo/i:
PCDA
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Livello qualitativo
Saggio
≥97% (HPLC)
Stato
crystals
Gruppo funzionale
carboxylic acid
Stringa SMILE
CCCCCCCCCCCCC#CC#CCCCCCCCCC(O)=O
InChI
1S/C25H42O2/c1-2-3-4-5-6-7-8-9-10-11-12-13-14-15-16-17-18-19-20-21-22-23-24-25(26)27/h2-12,17-24H2,1H3,(H,26,27)
ZPUDRBWHCWYMQS-UHFFFAOYSA-N
Categorie correlate
Applicazioni
10,12-Pentacosadiynoic acid (PCDA) is an amphiphilic diacetylene that can be used:
- In combination with a semifluorinated tetracosane ((CF3(CF2)7(CH2)15CH3) to synthesize mixed monolayer by photopolymerization.
- For the conversion of hydrophobic upconverting nanoparticles (UCNPs) to hydrophilic.
- To synthesize a polymer by combining with pyridine-2-aldoxime for colorimetric detection of malathion.
- To synthesize a thermochromic sensor constituting polymer fibres with monomeric unit of two PCDA linked by a p-phenylene group (bis-PCDA-Ph).
- As an inert coating material upon self-assembly and photopolymerization to modify the surface of Fe3O4 nanoparticles.
Avvertenze
Warning
Indicazioni di pericolo
Consigli di prudenza
Classi di pericolo
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
Organi bersaglio
Respiratory system
Codice della classe di stoccaggio
11 - Combustible Solids
Classe di pericolosità dell'acqua (WGK)
WGK 3
Punto d’infiammabilità (°F)
Not applicable
Punto d’infiammabilità (°C)
Not applicable
Dispositivi di protezione individuale
dust mask type N95 (US), Eyeshields, Gloves
Scegli una delle versioni più recenti:
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
I clienti hanno visto anche
Nanoscale, 9(2), 869-874 (2016-12-21)
A flexible, transparent, and portable wrist strap sensor device has been well developed from a hierarchical polydiacetylene/MoS
International journal of nanomedicine, 8, 221-232 (2013-02-14)
In this study, we immobilized polydiacetylene vesicles (PDAVs) onto the surface of polystyrene (PS) microspheres (1 μm in diameter) by using both electrical charge and conjugated forces to form a reinforced composite structure. These reinforced complexes could be easily washed
One and a half layers? Mixed Langmuir monolayer of 10, 12-pentacosadiynoic acid and a semifluorinated tetracosane.
Langmuir, 16(6), 2882-2886 (2000)
Chemistry (Weinheim an der Bergstrasse, Germany), 23(33), 8032-8038 (2017-04-13)
Circularly polarized light (CPL) is considered to be a true chiral entity and has been suggested as an explanation for the introduction of initial chiral biases into key biomolecular building blocks. CPL used recently asymmetric photochemical reactions is of wavelengths
Nature communications, 4, 2461-2461 (2013-09-13)
As they have been designed to undergo colorimetric changes that are dependent on the polarity of solvents, the majority of conventional solvatochromic molecule based sensor systems inevitably display broad overlaps in their absorption and emission bands. As a result, colorimetric
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.