Passa al contenuto
Merck
Tutte le immagini(1)

Key Documents

310980

Sigma-Aldrich

Gold

wire, diam. 0.5 mm, 99.99% trace metals basis

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula empirica (notazione di Hill):
Au
Numero CAS:
Peso molecolare:
196.97
Numero CE:
Numero MDL:
Codice UNSPSC:
12141717
ID PubChem:
NACRES:
NA.23

Livello qualitativo

Saggio

99.99% trace metals basis

Forma fisica

wire

Resistività

2.05 μΩ-cm, 0°C

Diametro

0.5 mm

P. eboll.

2808 °C (lit.)

Punto di fusione

1063 °C (lit.)

Densità

19.3 g/mL at 25 °C (lit.)

Stringa SMILE

[Au]

InChI

1S/Au
PCHJSUWPFVWCPO-UHFFFAOYSA-N

Quantità

380 mg = 10 cm; 1.9 g = 50 cm

Codice della classe di stoccaggio

11 - Combustible Solids

Classe di pericolosità dell'acqua (WGK)

nwg

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable

Dispositivi di protezione individuale

Eyeshields, Gloves, type N95 (US)


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 7

1 of 7

Gold wire, 0.025 mm diameter, length 20 m, purity 99.99+%

GF20443542

Gold

Gold wire, diam. 0.25 mm, 99.99% trace metals basis

Sigma-Aldrich

265780

Gold

Palladium wire, diam. 0.5 mm, 99.9% trace metals basis

Sigma-Aldrich

348694

Palladium

Platinum wire, diam. 0.5 mm, 99.99% trace metals basis

Sigma-Aldrich

267201

Platinum

Platinum wire, diam. 0.5 mm, 99.9% trace metals basis

Sigma-Aldrich

267228

Platinum

Gold beads, 1-6 mm, 99.999% trace metals basis

Sigma-Aldrich

326542

Gold

Tae-Sik Cho et al.
Journal of nanoscience and nanotechnology, 13(5), 3711-3714 (2013-07-19)
The crystallization of Au/glass ultrathin films for surface plasmon resonance (SPR) biosensor has been studied using synchrotron X-ray scattering and field emission scanning electron microscope. In films thinner than 30 nm, crystallized Au grains with [111] preferred orientation were formed
Yoon-Chae Nah
Journal of nanoscience and nanotechnology, 13(5), 3470-3473 (2013-07-19)
Au nanoparticles and poly(3-hexylthiophene) (P3HT) composite films were prepared by electrodeposition of Au nanoparticles using pulse-current electrodeposition followed by the spin coating of P3HT and their enhanced electrochromic coloration was investigated. A relatively uniformed Au nanoparticle was obtained by the
Young Min Bae et al.
Journal of biomedical nanotechnology, 9(6), 1060-1064 (2013-07-19)
We report on the enhancement of sensitivity of SPR biosensor by modifying the metal surface. A mixture layer, in which gold and dielectric medium coexist, was simply prepared by increasing the roughness of gold surface deposited onto a glass substrate
Midas touch in cardiology.
Marianna Karamanou et al.
European heart journal, 34(20), 1463-1464 (2013-07-11)
Young Joo Choi et al.
Journal of nanoscience and nanotechnology, 13(6), 4437-4445 (2013-07-19)
Gold nanorods (Au NRs) that absorb near-infrared (NIR) light have great potential in the field of nanomedicine. Photothermal therapy (PTT), a very attractive cancer therapy in nanomedicine, combines nanomaterials and light. The aim of this study was to elucidate the

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.