Poly(methyl methacrylate)

average Mw ~350,000 by GPC

Synonym(s):

PMMA, Poly(methacrylic acid methyl ester)

Sign Into View Organizational & Contract Pricing


About This Item

Linear Formula:
[CH2C(CH3)(CO2CH3)]n
CAS Number:
MDL number:
UNSPSC Code:
12352300
PubChem Substance ID:
NACRES:
NA.23

form

powder

Quality Level

autoignition temp.

580 °F

mol wt

average Mw ~350,000 by GPC

reduced viscosity

150-160 cm3/g(20 °C)(lit.)

acid number

<1 mg KOH/g

transition temp

Tg (DSC) 105 °C (midpoint)

solubility

alcohols and aliphatic hydrocarbons: insoluble
esters, ketones, aromatics and glycol ethers: soluble

density

1.17 g/mL at 25 °C

InChI

1S/C5H9O2/c1-4(2)5(6)7-3/h1-3H3

InChI key

PMAMJWJDBDSDHV-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

General description

The thermal degradation behaviour of PMMA ( avg Mol. wt. ~350,000 g mol-1)was investigated in inert atmosphere, four weight loss steps were observed.

Application

PMMA (avg. Mol wt. ~350,000 g mol-1) containing Fe2O3 and TiO2 fillers have possible uses as flame retardants.
Pigment-wetting binder for coatings.

Features and Benefits

Contributes hardness, weather resistance, light fastness and resistance to chemicals.

Storage Class Code

11 - Combustible Solids

WGK

nwg

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Influence of TiO2 and Fe2O3 fillers on the thermal properties of poly (methyl methacrylate)(PMMA).
Laachachi A.,et al.
Material Matters, 59(1), 36-39 (2005)
Thermal degradation of poly (methyl methacrylate)(PMMA): modelling of DTG and TG curves.
Ferriol M., et al.
Polymer Degradation and Stability, 79(2), 271-281 (2003)
Pleural infection 55 years after plombage for pulmonary tuberculosis.
Qian-kun Chen et al.
Asian cardiovascular & thoracic annals, 21(1), 100-100 (2013-02-23)
Gursukhman S Sidhu et al.
Journal of neurosurgery. Spine, 19(1), 61-70 (2013-05-07)
The authors endeavor to highlight the surgical management of severe neurological deficit resulting from cement leakage after percutaneous vertebroplasty and to systematically review the literature on the management of this complication. A patient presented after a vertebroplasty procedure for traumatic
S A Bini et al.
The bone & joint journal, 95-B(3), 367-370 (2013-03-02)
We evaluated the impact of pre-coating the tibial component with polymethylmethacrylate (PMMA) on implant survival in a cohort of 16 548 primary NexGen total knee replacements (TKRs) in 14 113 patients. In 13 835 TKRs a pre-coated tray was used

Articles

The detection and quantification of biomarkers are essential for medical diagnostics, environmental monitoring, and bioresearch.

Professor Aran (Claremont University, USA) thoroughly discusses the engineering of graphene based materials through careful functionalization of graphene oxide, a solution processable form of graphene.

Developed in the last several years, fluorescence quenching microscopy (FQM) has enabled rapid, inexpensive, and high-fidelity visualization of two-dimensional (2D) materials such as graphene-based sheets and MoS2.

We will explore the technological advances that have contributed toward the progress of 3DP of tissue engineering scaffolds, current materials used to create 3DP scaffolds, and the challenges that remain.

See All

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service