HADK1MAG-61K
MILLIPLEX® Human Adipokine Magnetic Bead Panel 1 - Endocrine Multiplex Assay
The Human Adipokine Panel 1, using the Luminex xMAP technology, enables the simultaneous analysis of five biomarkers in human serum or plasma samples.
About This Item
推荐产品
品質等級
物種活性
human
製造商/商標名
Milliplex®
assay range
accuracy: 87%
(Resistin)
accuracy: 89%
(Adiponectin)
sensitivity: 10 pg/mL
(MinDC+2SD; Adipsin)
sensitivity: 21 pg/mL
(MinDC+2SD; Adiponectin)
sensitivity: 3.5 pg/mL
(MinDC+2SD; Lipocalin-2/NGAL)
sensitivity: 4.4 pg/mL
(MinDC+2SD; Resistin)
sensitivity: 5.8 pg/mL
(MinDC+2SD; PAI-1)
standard curve range: 13-200,000 pg/mL
(Adipsin)
standard curve range: 26-400,000 pg/mL
(Adiponectin)
standard curve range: 3.2-50,000 pg/mL
(Lipocalin-2/NGAL)
standard curve range: 6.4-100,000 pg/mL
(Resistin)
standard curve range: 9.6-150,000 pg/mL
(PAI-1 (total))
inter-assay cv: <10%
intra-assay cv: <10%
(Adipsin)
inter-assay cv: <10%
intra-assay cv: <15%
(Adiponectin)
inter-assay cv: <10%
intra-assay cv: <15%
(Lipocalin-2/NGAL)
inter-assay cv: <10%
intra-assay cv: <20%
(PAI-1 (total))
inter-assay cv: <10%
intra-assay cv: <20%
(Resistin)
技術
multiplexing: suitable
檢測方法
fluorometric (Luminex xMAP)
運輸包裝
wet ice
一般說明
The MILLIPLEX® Human Adipokine Panel 1 is a 5-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum or plasma samples: Adiponectin, Adipsin, Lipocalin-2/NGAL, Total PAI-1, and Resistin. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
應用
- Analytes: Adiponectin Adipsin Lipocalin-2/NGAL PAI-1 (Total) Resistin
- Recommended Sample Type: Human serum and plasma
- Recommended Sample Dilution: 25 μL per well of 1:400 diluted serum or plasma
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Endocrine
特點和優勢
其他說明
法律資訊
訊號詞
Danger
危險分類
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
儲存類別代碼
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
相关内容
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门