Accéder au contenu
Merck
  • Simultaneous determination of bambuterol and its two major metabolites in human plasma by hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry.

Simultaneous determination of bambuterol and its two major metabolites in human plasma by hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-08-17)
Ting Zhou, Qing Cheng, Chengjuan Zou, Ting Zhao, Shan Liu, Marco Pistolozzi, Evina Tan, Ling Xu, Wen Tan
RÉSUMÉ

In this study, a rapid and sensitive hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry (HILIC-UPLC-MS/MS) method was developed for simultaneous determination of bambuterol and its two major metabolites monocarbamate bambuterol and terbutaline in human plasma. All samples were simply precipitated using acetonitrile and separated on a UPLC-HILIC column under gradient elution with a mobile phase consisting of acetonitrile and water with the addition of 10mm ammonium acetate and 0.1% formic acid at 0.4 mL/min. The analytes were detected by a Xevo TQ-S tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. The established method was highly sensitive with the lower limit of quantification (LLOQ) of 10.00 pg/mL for each analyte, and the intra- and inter-day precisions were <12.8%. The analytical runtime within 4.0 min per sample made this method suitable for high throughput determination. The validated method was successfully applied to a clinical pharmacokinetic study of bambuterol in eight healthy volunteers. Furthermore, the effects of the chromatographic conditions on the retention of the analytes on HILIC were investigated, and the benefits of HILIC were evaluated by comparing with a C18 column. The results indicated that liquid-liquid partition and the electrostatic interactions played an important role in the retention of the analytes on HILIC in this study. And HILIC offered particular advantages over RPLC approach in the aspects of the peak symmetry, the column efficiency, and the column pressure.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acétate d'éthyle, ACS reagent, ≥99.5%
Sigma-Aldrich
Acétonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acétate d'éthyle, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Acide formique, reagent grade, ≥95%
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acétate d'éthyle, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Carbonate de sodium, powder, ≥99.5%, ACS reagent
Sigma-Aldrich
Acide formique, ACS reagent, ≥96%
Sigma-Aldrich
Acétate d′ammonium, ACS reagent, ≥97%
Sigma-Aldrich
Acétonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Carbonate de sodium, ACS reagent, anhydrous, ≥99.5%, powder or granules
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Sigma-Aldrich
Méthanol, anhydrous, 99.8%
Sigma-Aldrich
Acétate d′ammonium, ≥99.99% trace metals basis
Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Supelco
Acétate d′ammonium, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%