Accéder au contenu
Merck
  • Simultaneous determination of seventeen mycotoxins residues in Puerariae lobatae radix by liquid chromatography-tandem mass spectrometry.

Simultaneous determination of seventeen mycotoxins residues in Puerariae lobatae radix by liquid chromatography-tandem mass spectrometry.

Journal of pharmaceutical and biomedical analysis (2014-06-18)
Shufang Wang, Ling Cheng, Shen Ji, Ke Wang
RÉSUMÉ

This work reported an efficient and accurate liquid chromatography tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of seventeen mycotoxins in Puerariae lobatae radix, a frequently used traditional Chinese medicine (TCM). The effects of four different clean-up methods, including TC-M160, TC-T220, Mycosep 227, and QuEChERS method, on the recoveries of mycotoxins were investigated and compared. Finally, TC-M160 was chosen for better recovery and repeatability for mycotoxins analysis. The analytes were separated on an Agilent ZORBAX SB C18 column (4.6mm×250mm, 5μm particle size), and eluted with a mobile phase consisting of (A) water containing 0.1% formic acid and (B) acetonitrile containing 0.1% formic acid at a flow rate of 0.6mL/min. The separated compounds were detected by a triple quadrupole mass spectrometer operating in positive electrospray ionization with multiple reaction monitoring (MRM) mode. The results of method validation accorded with the requirement of analytical method for mycotoxins in COMMISSION REGULATION (EC) No 401/2006. The developed method was successfully applied for determination of mycotoxins in seventeen batches of Puerariae lobatae radix collected from different provinces of China. Three batches of them were found with contamination of mycotoxins AFB1 at (0.751±0.176)μg/kg, T-2 at (1.10±0.01)μg/kg, and T-2 at (0.853±0.044)μg/kg, respectively. The results demonstrated that the proposed method was suitable for monitoring mycotoxins residues in Puerariae lobatae radix.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acétonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acétonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Sigma-Aldrich
Méthanol, Absolute - Acetone free
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
USP
Méthanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acétonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Méthanol, anhydrous, 99.8%
Sigma-Aldrich
Zearalenone, fungal mycotoxin
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acétonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acétonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acétonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Supelco
Acétonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Méthanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Zearalanone
Supelco
Méthanol, analytical standard
Sigma-Aldrich
Alternariol monomethyl ether from Alternaria alternata (tenuis)
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Méthanol, NMR reference standard
Sigma-Aldrich
HT-2 Toxin, ≥98% (HPLC)