Accéder au contenu
Merck
Toutes les photos(2)

Documents

54182-U

Supelco

Supel-Select HLB SPE Tube

bed wt. 60 mg, volume 3 mL, pk of 50

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41115712
Nomenclature NACRES :
NB.21

Matériaux

PE frit (20 μm)
polypropylene hardware

Qualité

MS friendly

Composition

bed wt., 60 mg

Conditionnement

pk of 50

Technique(s)

solid phase extraction (SPE): suitable

Superficie

160-420 m2/g

Volume

3 mL

Matrice

Hydrophilic modified styrene polymer particle platform

Groupe de la matrice active

polystyrene phase

Taille des particules

50-70 μm

Dimension de pores

80-200 Å pore size

Application(s)

food and beverages

Technique de séparation

reversed phase

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Retention Mechanism: Reversed-phase
Sample Matrix Compatibility: Aqueous solutions (biological fluids, water)

  • Hydrophilic modified styrene polymer
  • Developed for the extraction of a highly broad range of compounds from aqueous samples
  • Retention predominately based on reversed-phase; however, because the phase is hydrophilic modified, it is amenable to polar compounds as well.
  • Examples of more polar compounds that are retained and recovered include (but not limited to): pyridoxine (logPo/w -0.56), riboflavin (logPo/w -2.02), biotin (logPo/w 0.11).

Application

Supel-Select HLB SPE Tube may be used as an extraction cartridge for the solid phase extraction and determination of antibiotics in water samples using liquid chromatography electrospray ionization tandem mass spectrometry.

Caractéristiques et avantages

  • Excellent sample prep performance at a lower price
  • Amenable to generic methodology - save time, money, and headache during method development
  • Greater capacity allows for smaller bed weights = smaller elution volumes = time savings in sample processing
  • Resistance to overdrying allows for more robust methdology
  • Low UV and MS extractables for lower background and greater sensitivity
  • Stringent production and QC guidelines offer greater lot-to-lot, tube-to-tube, and well-to-well consistency for improved accuracy and precision

Informations légales

Supel is a trademark of Sigma-Aldrich Co. LLC

Code de la classe de stockage

13 - Non Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°C)

Not applicable


Choose from one of the most recent versions:

Certificats d'analyse (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Analysis of selected antibiotics in surface freshwater and seawater using direct injection in liquid chromatography electrospray ionization tandem mass spectrometry
Bayen S, et al.
Journal of Chromatography A, 1338, 38-43 (2014)
Chiedza F Munyeza et al.
Biomedical chromatography : BMC, 30(6), 837-845 (2015-09-18)
Tigecycline (TIG), a derivative of minocycline, is the first in the novel class of glycylcyclines and is currently indicated for the treatment of complicated skin structure and intra-abdominal infections. A selective, accurate and reversed-phase high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS)
Pablo Vazquez-Roig et al.
Analytical and bioanalytical chemistry, 397(7), 2851-2864 (2010-05-01)
A simple and robust method using solid-phase extraction (SPE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 14 drugs of abuse and their metabolites (cocainics, amphetamine-like compounds, cannabinoids, and opiates) in surface waters has been developed.
Wei Chen et al.
Chemosphere, 163, 99-107 (2016-08-16)
A sensitive method for simultaneous determination of 20 trace organic chemicals (TOrCs, including preservatives, antioxidants, disinfectants, oestrogens, alkyl-phenols and bisphenol-A) in surface water and wastewater has been developed and validated based on the optimisation of solid-phase extraction (SPE) followed by
Martina Rejtharová et al.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment, 34(4), 477-481 (2016-12-06)
Monitoring of steroid esters in blood serum is desirable in order to detect the possible illegal use of natural hormones as growth promoters. A method for the determination of testosterone propionate, testosterone benzoate, testosterone isocaproate, testosterone decanoate and estradiol benzoate

Articles

Select HLB SPE is a hydrophilic polymer phase for analyte extraction from aqueous matrices. Here it’s used for statins in plasma and 48 pharmaceutical analytes in drinking water.

Reversed-phase interaction will retain most molecules with hydrophobic character; it is very useful for extracting analytes that are very diverse in structure within the same sample.

Protocoles

Protocol for LC MS Analysis of Triclosan Irgasan in Waste Water

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique