68172
Hydrocarbon Index-Kit acc. to DIN EN ISO 9377-2/H53
Synonyme(s) :
DIN EN ISO 9377-2, Kit, H53-Kit
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Durée de conservation
limited shelf life, expiry date on the label
Niveau de qualité
Application(s)
environmental
Application
application test according EN ISO 9377- 2/H53 : in accordance
The kit allows users to extract and analyze 20 water samples (2 series of 10 water samples) in duplicate. Recovery and Blank analysis should be run in duplicate after each series.
The following solutions should be diluted as follows prior to use:
49574 - 1:10with n-heptane
51706 - 1:10with acetone (exact concentration should be a thousand times the desired application range)
The water sample is extracted with an extracting agent. Polar substances are removed by clean up on Florisil®. The purified aliquot is analyzed by capillary chromatography using a non-polar column and a flame ionization detector. The total peak area between n-decane and n-tetracontane is measured. The concentration of mineral oil is quantified against and external standard consisting of two specified mineral oils, and the hydrocarbon oil index is calculated.
The kit allows users to extract and analyze 20 water samples (2 series of 10 water samples) in duplicate. Recovery and Blank analysis should be run in duplicate after each series.
The following solutions should be diluted as follows prior to use:
49574 - 1:10with n-heptane
51706 - 1:10with acetone (exact concentration should be a thousand times the desired application range)
The water sample is extracted with an extracting agent. Polar substances are removed by clean up on Florisil®. The purified aliquot is analyzed by capillary chromatography using a non-polar column and a flame ionization detector. The total peak area between n-decane and n-tetracontane is measured. The concentration of mineral oil is quantified against and external standard consisting of two specified mineral oils, and the hydrocarbon oil index is calculated.
Informations légales
Florisil is a registered trademark of U.S. Silica Company
Composants de kit également disponibles séparément
Réf. du produit
Description
FDS
- 52582-USupelclean™ Florisil®/Na2SO4 SPE Tube, glass hardware, PTFE frit, bed A 2 g (Florisil®), bed B 2 g (Na2SO4), volume 6 mL, pk of 48 pk 48FDS
- 18602Mineral oil standard mixture Type A and B for EN ISO 9377-2, analytical standard, ~10 mg/mL in heptane (exact content on the reference material certificate) 10 mLFDS
- 51706QC-Standard Solution for EN ISO 9377-2, analytical standard 1 mLFDS
- 49574Extraction Medium Stock Solution, acc. to DIN EN ISO 9377-2 3 x 100 mLFDS
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Carc. 2 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3
Organes cibles
Central nervous system
Code de la classe de stockage
3 - Flammable liquids
Point d'éclair (°F)
-0.4 °F
Point d'éclair (°C)
-18 °C
Faites votre choix parmi les versions les plus récentes :
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique