68172

Supelco

Hydrocarbon Index-Kit acc. to DIN EN ISO 9377-2/H53

Synonyme(s) :

DIN EN ISO 9377-2, Kit, H53-Kit

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41113319
Nomenclature NACRES :
NA.21

Durée de conservation

limited shelf life, expiry date on the label

Niveau de qualité

Application(s)

environmental

Application

application test according EN ISO 9377- 2/H53 : in accordance

The kit allows users to extract and analyze 20 water samples (2 series of 10 water samples) in duplicate. Recovery and Blank analysis should be run in duplicate after each series.

The following solutions should be diluted as follows prior to use:
49574 - 1:10with n-heptane
51706 - 1:10with acetone (exact concentration should be a thousand times the desired application range)
The water sample is extracted with an extracting agent. Polar substances are removed by clean up on Florisil®. The purified aliquot is analyzed by capillary chromatography using a non-polar column and a flame ionization detector. The total peak area between n-decane and n-tetracontane is measured. The concentration of mineral oil is quantified against and external standard consisting of two specified mineral oils, and the hydrocarbon oil index is calculated.

Informations légales

Florisil is a registered trademark of U.S. Silica Company

Composants de kit également disponibles séparément

Réf. du produit
Description
FDS

  • 52582-USupelclean Florisil®/Na2SO4 SPE Tube, glass hardware, PTFE frit, bed A 2 g (Florisil®), bed B 2 g (Na2SO4), volume 6 mL, pk of 48 pk 48FDS

  • 18602Mineral oil standard mixture Type A and B for EN ISO 9377-2, analytical standard, ~10 mg/mL in heptane (exact content on the reference material certificate) 10 mLFDS

  • 51706QC-Standard Solution for EN ISO 9377-2, analytical standard 1 mLFDS

  • 49574Extraction Medium Stock Solution, acc. to DIN EN ISO 9377-2 3 x 100 mLFDS

Mention d'avertissement

Danger

Classification des risques

Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Carc. 2 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

Organes cibles

Central nervous system

Code de la classe de stockage

3 - Flammable liquids

Point d'éclair (°F)

-0.4 °F

Point d'éclair (°C)

-18 °C


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique