1.51015
TLC aluminum sheets, silica gel 60 RP-18 F254s MS-grade
pkg of 20 sheets, sheet L × W 5 cm × 7.5 cm, aluminum support
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Matériaux
aluminum support
silica gel 60 matrix
Niveau de qualité
Caractéristiques
binder Organic Polymer
fluorescent indicator
Conditionnement
pkg of 20 sheets
Technique(s)
TLC-MS: suitable
thin layer chromatography (TLC): suitable
Épaisseur de la couche
100 μm
Feuille, L × l
5 cm × 7.5 cm
Taille des particules
10-12 μm
Dimension de pores
60 Å medium pore diameter
Température de stockage
2-30°C
Description générale
20 Aluminium sheets 5x7.5
Reference:
Gertrud Morlock, Wolfgang Schwack
Coupling of planar chromatography to mass spectrometry
TrAC Trends in Analytical Chemistry, Volume 29, Issue 10, 2010, Pages 1157-1171
Gertrud Morlock, Wolfgang Schwack
Coupling of planar chromatography to mass spectrometry
TrAC Trends in Analytical Chemistry, Volume 29, Issue 10, 2010, Pages 1157-1171
Remarque sur l'analyse
Specific surface area(according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume(N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution):9.7 - 11.7 µm
Layerthickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
A) Cholesterin test
hRf-values
- cholesterin: 35 - 43
B) Steroid test
- methyltestosterone: 14 - 24
- Reichstein S: 28 - 38- hydrocortisone: 40 - 50
Typical value determined on an activated sheet (120°C, 15 min)
Eluent A) aceton/ water (95/5 v/v)
Eluent B) aceton/ water (60/40 v/v)
C) MS suitability test
- Angiotensin II (signal-to-noiseratio 50ng): ≥ 25
measured with 5000 shots
- Caffeine (signal-to-ratio 5ng): ≥25
Pore volume(N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution):9.7 - 11.7 µm
Layerthickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
A) Cholesterin test
hRf-values
- cholesterin: 35 - 43
B) Steroid test
- methyltestosterone: 14 - 24
- Reichstein S: 28 - 38- hydrocortisone: 40 - 50
Typical value determined on an activated sheet (120°C, 15 min)
Eluent A) aceton/ water (95/5 v/v)
Eluent B) aceton/ water (60/40 v/v)
C) MS suitability test
- Angiotensin II (signal-to-noiseratio 50ng): ≥ 25
measured with 5000 shots
- Caffeine (signal-to-ratio 5ng): ≥25
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique