1.15973
Weigert′s iron hematoxylin kit
for nuclear staining in histology
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Niveau de qualité
IVD
for in vitro diagnostic use
Application(s)
clinical testing
diagnostic assay manufacturing
hematology
Température de stockage
15-25°C
Description générale
Weigert′s iron hematoxylin kit - for nuclear staining in histology is a ready to use staining kit used for human-medical cell diagnosis and serves the purpose of the histological investigation of sample material of human origin, for example histological sections of e. g. the liver, the kidney, the intestine, the placenta and similar. Aluminium hematoxylins (e. g. nuclear fast red aluminium sulfate) are washed out of the tissue sections by acidic staining solutions. Iron hematoxylin solutions (e. g. Weigert′s iron hematoxylin), on the other hand, are acid-resistant and are preferentially used for staining nuclei in histological tissue sections in which counterstaining is done with acidic staining solutions. Examples here include the visualization of elastic fibers according to the van Gieson method (e. g. Elastica van Gieson (Product number 1.15974)) and the various trichromo connective-tissue staining methods (e. g. according to Masson-Goldner (Product number 1.00485). Commonly used hemalum solutions such as Mayer′s Hemalum, Delafield, Gill and Harris tend to procedure also weak nucleic staining only when used with acidic counter-stains.The kit contains two solutions; an alcoholic hematoxylin solution and a hydrochloric acid iron(III)nitrate solution, which are ready-to-use and should be applied at 3-5 μm paraffin sections.
The package is sufficient for 400 - 500 applications. Weigert′s Iron hematoxylin kit is an IVD & CE product and can be used in the clinical laboratory for diagnostics. For more details, please see instructions for use (IFU). The IFU can be downloaded from this webpage.
The package is sufficient for 400 - 500 applications. Weigert′s Iron hematoxylin kit is an IVD & CE product and can be used in the clinical laboratory for diagnostics. For more details, please see instructions for use (IFU). The IFU can be downloaded from this webpage.
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Eye Irrit. 2 - Flam. Liq. 2 - Met. Corr. 1
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 1
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Frontiers in physiology, 10, 1445-1445 (2020-01-11)
Adipose-derived stem cells (ADSCs) have shown great promise for the treatment of myocardial infarction (MI), although their potential therapeutic mechanism remains poorly understood. Growing evidence has implicated microRNAs (miRNAs or miRs) in the biological processes whereby ADSCs could ameliorate cardiovascular
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique