1.09889
Buffer concentrate
(boric acid/potassium chloride/sodium hydroxide), traceable to SRM of NIST and PTB for 500 ml buffer solution, pH 9.00 ± 0.02 (20°C) Titrisol®
Synonyme(s) :
Buffer concentrate for 500 ml buffer solution, pH 9.00 ± 0.02 (20°C)
About This Item
Produits recommandés
Qualité
analytical standard
Niveau de qualité
Agence
according to DIN 19266
Gamme de produits
Titrisol®
pH
8.9 (20 °C in H2O)
Densité
1.00 g/cm3 at 20 °C
Application(s)
environmental
food and beverages
general analytical
industrial qc
pharmaceutical
Format
mixture
Température de stockage
15-25°C
Description générale
Application
- Buffer concentrate in viral nucleic acid preamplification: A study utilized buffer concentrate in various viral nucleic acid preamplification pipelines for sewage viral metagenomics, enhancing the accuracy and efficiency of viral detection methods (Fernandez-Cassi and Kohn, 2024).
- Buffer concentrate in myocardial slice cultures: Research on rabbit myocardial slices demonstrated the critical role of buffer concentrate in maintaining tissue stability and function under various experimental conditions, crucial for physiological studies (Baron et al., 2024).
- Buffer concentrate in fluorescence spectroscopy: A study explored the interaction of erythrosine B with cardiac drugs, using buffer concentrate to stabilize reaction conditions in fluorescence, scattering, and absorbance spectroscopy (AlSalem et al., 2024).
- Buffer concentrate in solid-state NMR: The quantification of residual water in pharmaceutical solutions was improved using buffer concentrate in solid-state NMR, highlighting its importance in ensuring the quality and stability of pharmaceutical formulations (Du and Su, 2024).
- Buffer concentrate in electrochemical detection: Buffer concentrate facilitated the electrochemical detection of iodide in nuclear emergency tablets, proving essential for precise and reliable analytical applications in emergency response scenarios (Alqibthiyah et al., 2024).
Caractéristiques et avantages
- Traceable to primary standard reference materials from NIST and PTB
- Analytical standard Grade
- Uncertainty data and traceability are documented in a comprehensive and batch-specific Certificate of Analysis.
Remarque sur l'analyse
Measured after dilution to 500 ml with a combination glass electrode after multiple point calibration (according to DIN 19268) with reference materials for the preparation of standard buffer solutions according to DIN 19266.
Informations légales
Étalon
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Repr. 1B
Code de la classe de stockage
6.1D - Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
Classe de danger pour l'eau (WGK)
WGK 1
Point d'éclair (°F)
Not applicable
Point d'éclair (°C)
Not applicable
Listes réglementaires
Les listes réglementaires sont principalement fournies pour les produits chimiques. Seules des informations limitées peuvent être fournies ici pour les produits non chimiques. L'absence d'indication signifie qu'aucun des composants n'est répertorié. Il incombe à l'utilisateur de s'assurer de l'utilisation sûre et légale du produit.
EU REACH SVHC Candidate List
EU REACH Annex XVII (Restriction List)
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique