HMHEMAG-34K
MILLIPLEX® Human Metabolic Hormone Magnetic Bead Panel - Metabolism Multiplex Assay
The Human Metabolic Hormone Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 13 protein biomarkers in human serum, plasma and cell/tissue culture samples.
Synonym(s):
human metabolic hormone immunoassay panel, luminex human metabolic hormone multiplex assay, millipore human metabolism multiplex kit
About This Item
Recommended Products
species reactivity
human
manufacturer/tradename
Milliplex®
assay range
accuracy: 101%
(Glucagon)
accuracy: 102%
(Leptin)
accuracy: 103%
(GIP)
accuracy: 103%
(GLP-1 (Total))
accuracy: 105%
(Ghrelin (Active))
accuracy: 106%
(MCP-1)
accuracy: 97%
(TNFα)
accuracy: 99%
(C-Peptide)
sensitivity: 0.5 pg/mL
(MinDC+2SD; TNF?)
sensitivity: 1.1 pg/mL
(MinDC+2SD; GIP)
sensitivity: 13 pg/mL
(MinDC+2SD; IL-6)
sensitivity: 14 pg/mL
(MinDC+2SD; Ghrelin (Active))
sensitivity: 14 pg/mL
(MinDC+2SD; MCP-1)
sensitivity: 146 pg/mL
(MinDC+2SD; PYY)
sensitivity: 15 pg/mL
(MinDC+2SD; Amylin (Total))
sensitivity: 16 pg/mL
(MinDC+2SD; C-Peptide)
sensitivity: 16 pg/mL
(MinDC+2SD; Glucagon)
sensitivity: 160 pg/mL
(MinDC+2SD; Insulin)
sensitivity: 2.4 pg/mL
(MinDC+2SD; GLP-1 (Active))
sensitivity: 2.9 pg/mL
(MinDC+2SD; PP)
sensitivity: 28 pg/mL
(MinDC+2SD; Amylin (Active))
sensitivity: 64 pg/mL
(MinDC+2SD; Leptin)
sensitivity: 7.3 pg/mL
(MinDC+2SD; GLP-1 (Total))
standard curve range: 0.69-500 pg/mL
(TNFα)
standard curve range: 1.4-1,000 pg/mL
(GIP)
standard curve range: 13.7-10,000 pg/mL
(Amylin (Active))
standard curve range: 13.7-10,000 pg/mL
(Amylin (Total))
standard curve range: 13.7-10,000 pg/mL
(Ghrelin (Active))
standard curve range: 13.7-10,000 pg/mL
(Glucagon)
standard curve range: 13.7-10,000 pg/mL
(IL-6)
standard curve range: 13.7-10,000 pg/mL
(MCP-1)
standard curve range: 13.7-10,000 pg/mL
(PYY)
standard curve range: 137-100,000 pg/mL
(Insulin)
standard curve range: 137-100,000 pg/mL
(Leptin)
standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Active))
standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Total))
standard curve range: 2.7-2,000 pg/mL
(PP)
standard curve range: 27.4-20,000 pg/mL
(C-Peptide)
inter-assay cv: <15%
intra-assay cv: <10%
(C-Peptide)
inter-assay cv: <15%
intra-assay cv: <10%
(GIP)
inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Active))
inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Total))
inter-assay cv: <15%
intra-assay cv: <10%
(Ghrelin (Active))
inter-assay cv: <15%
intra-assay cv: <10%
(Glucagon)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <15%
intra-assay cv: <10%
(Insulin)
inter-assay cv: <15%
intra-assay cv: <10%
(Leptin)
inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1)
inter-assay cv: <15%
intra-assay cv: <10%
(PP)
inter-assay cv: <15%
intra-assay cv: <10%
(PYY)
inter-assay cv: <15%
intra-assay cv: <10%
(TNFα)
inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Active))
inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Total))
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex xMAP)
shipped in
wet ice
General description
The MILLIPLEX® Human Metabolic Hormone Panel is a 15 analyte, 13-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and cell/tissue culture samples: Amylin (Active) or Amylin (Total), C-Peptide, Ghrelin (Active), GIP, GLP-1 (Active) or GLP-1 (Total), Glucagon, IL-6, Insulin, Leptin, MCP-1, PP, PYY, TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
Application
- Analytes: Amylin (Active), Amylin (Total), C-Peptide, Ghrelin (Active), GIP (Total), GLP-1 (Active), GLP-1 (Total), Glucagon, IL-6, Insulin, Leptin, MCP-1 (CCL2), Pancreatic Polypeptide (PP), PYY (Total), TNF-α
- NOTE: The following analytes cannot be assayed simultaneously: Amylin (Active) & Amylin (Total); GLP-1 (Active) & GLP-1 (Total).
- Recommended Sample Type: Human serum, plasma, and cell/tissue culture supernatants or lysates
- Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma; cell/tissue culture samples may be used undiluted or diluted with an appropriate control medium NOTE: The following analytes require the addition of protease inhibitors to serum or plasma samples (see sample collection and storage section in the protocol for details): GLP-1 (DPPIV inhibitor); Amylin (protease inhibitor cocktail); Glucagon (Aprotinin); Ghrelin (Active) (serine protease inhibitor).
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Metabolic Disorders
Features and Benefits
Linkage
Other Notes
Legal Information
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service