Saltar al contenido
Merck
  • Development and validation of a hydrophilic interaction liquid chromatography with tandem mass spectrometry method for the simultaneous detection and quantification of etilefrine and oxilofrine in equine blood plasma and urine.

Development and validation of a hydrophilic interaction liquid chromatography with tandem mass spectrometry method for the simultaneous detection and quantification of etilefrine and oxilofrine in equine blood plasma and urine.

Journal of separation science (2014-08-22)
Noel Kong, Rong Yi, Sarah Zhao, Jasmeet Sandhu, Geoffrey Lam, Devan Loganathan, Barbara Morrissey
RESUMEN

A sensitive hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry method was developed and validated for the simultaneous detection and quantification of etilefrine and oxilofrine in equine blood plasma and urine. The method is highly sensitive and specific with good precision and accuracy. In plasma the limit of detection and limit of quantification are 0.03 and 0.1 ng/mL, respectively, for both analytes. In urine the limit of detection and limit of quantification are 0.3 and 1 ng/mL, respectively, for both analytes. The suitability of the method for doping control analysis in equine species is demonstrated by analyzing postadministration samples collected after a single intravenous administration of 50 mg etilefrine to a standardbred mare. Etilefrine was detected up to 120 h in urine and up to 48 h in plasma. Etilefrine is highly conjugated in equine urine whereas it exists in the free form in equine plasma. Therefore, enzyme hydrolysis prior to sample preparation is recommended for the detection and quantification of etilefrine and oxilofrine in equine urine.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Hidróxido de amonio solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ácido fórmico, reagent grade, ≥95%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Terc-butilmetil éter, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Ácido fórmico, ACS reagent, ≥96%
Sigma-Aldrich
Hidróxido de amonio solution, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
Acetonitrilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Terc-butilmetil éter, ACS reagent, ≥99.0%
Sigma-Aldrich
Ammonia solution, 7 N in methanol
Sigma-Aldrich
Formato de amonio, reagent grade, 97%
Sigma-Aldrich
Tetraborato de sodio decahydrate, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetato de sodio trihydrate, ACS reagent, ≥99%
Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Terc-butilmetil éter, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Formato de amonio, ≥99.995% trace metals basis
Sigma-Aldrich
Tetraborato de sodio decahydrate, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Acetato de sodio trihydrate, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Ácido fórmico, ACS reagent, ≥88%
Sigma-Aldrich
Terc-butilmetil éter, reagent grade, ≥98%
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Metanol, Absolute - Acetone free
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Metanol, BioReagent, ≥99.93%
Sigma-Aldrich
ββ-Glucuronidasa from Helix pomatia, Type H-2, aqueous solution, ≥85,000 units/mL