Saltar al contenido
Merck
Todas las fotos(1)

Documentos clave

G005799

GC Analysis of Pesticides in Beef Kidney on SLB®-5ms (20 m x 0.18 mm I.D., 0.36 μm) after QuEChERS Cleanup using Supel Que Z-Sep+, MS in SIM Mode, Fast GC Analysis

suitable for GC, application for SPE

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

técnicas

gas chromatography (GC): suitable
solid phase extraction (SPE): suitable

parámetros analíticos

sample preparation: Dispersive (QuEChERS)
sample/matrix: 10 gm homogenized beef kidney spiked at 50 ng/g with pesticides
extraction tube: Supel Que Acetate (AC) Tube (55234-U)
extraction process: add 10 mL of acetonitrile; shake for 1 minute; add contents of Supel Que acetate extraction tube (55234-U); shake immediately for 1 minute; centrifuge at 3200 rpm for 5 minutes; (Sample Pretreatment: Homogenize 10 gm beef kidney and spike with pesticides at 50 ng/g.)
clean-up tube: Supel QuE Z-Sep+ tube (55296-U)
clean-up process: transfer 3 mL of the acetonitrile layer into a Supel QuE Z-Sep+ cleanup tube (55296-U); shake for 1 minute; centrifuge at 3400 rpm for 3 minutes; draw off supernatant for LVI-GCMS analysis
column: F.S. CAP. SLB-5MS 20 m x 0.18 mm I.D., 0.36 μm (28576-U)
oven: 70 °C ( 0.5 min), 25 °C/min to 125 °C, 10 °C/min to 200 °C, 5 °C/min to 300 °C/min (1 min)
inj. temp.: programmed, 60 °C (0.28 min), 600 °C/min to 325 °C (5 min)
detector: MSD
MSD interface: 325 °C
carrier gas: helium, 1 mL/min constant flow
injection: 10 μL LVI, PTV solvent vent, rapid injection speed
liner: 4 mm ID FocusLiner with taper
sample: Beef Kidney extract

idoneidad

application for SPE

aplicaciones

food and beverages

Nota de análisis

Beef kidney was analyzed for pesticides by GC/MS-SIM after extraction and cleanup. Dispersive SPE was used for both extraction and cleanup. Since beef kideny contains approximately 5% fat, Z-Sep + was used for cleanup.

Información legal

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany
Supel is a trademark of Sigma-Aldrich Co. LLC

Analito

Descripción

    Diphenylamine
    Hexachlorobenzene
    Lindane
    Endosulfan I
    4,4′-DDE
    1,1-Dichloro-2,2-bis(4-chlorophenyl)ethane
    Endosulfan sulfate
    4,4′-DDT
    Piperonylbutoxide
    Bifenthrin
    Permethrin (isomers) solution
    Ver todo (11)

tubo o placa de SPE

Referencia del producto
Descripción
Precios

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

Lo sentimos, en este momento no disponemos de COAs para este producto en línea.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico