Saltar al contenido
Merck

MFGL04GF3

Millipore

Durapore® 0,22 µm, cápsula de llenado final Millipak®

non-sterile (non-sterilized), Millipak® Final Fill 40, pore size 0.22 μm

Sinónimos:

Millipak® Final Fill 40

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
23151806

Materiales

PVDF membrane
polysulfone device
polysulfone support

Nivel de calidad

Agency

certified by the ISO 9001:2015 (Quality Management Systems)
meets requirements for EP 2.6.14
meets requirements for JP 4.01
meets requirements for USP 85

esterilidad

irradiated
non-sterile (non-sterilized)

Compatibilidad de esterilización

gamma compatible

Línea del producto

Millipak® Final Fill 40

Características

hydrophilic

envase

bag of 3 × double easy-open bag

Parámetros

1.0 L/min flow rate at 0.69 bar
10 psi max. differential pressure (0.7 bar) at 25 °C (Reverse)
25 psi max. differential pressure (1.7 bar) at 25 °C (Forward)
50 psi max. differential pressure (3.5 bar) at 25 °C (Forward)
60 psi max. differential pressure (4.1 bar) at 25 °C (Forward)
60 psi max. inlet pressure (4.1 bar) at 25 °C
80 psi max. differential pressure (5.5 bar) at 25 °C (Forward)
80 psi max. inlet pressure (5.5 bar) at 25 °C

técnicas

sterile filtration: suitable

Longitud

3.4 in.

Anchura

3.0 in.

filtración área

200 cm2

impurezas

<0.25 EU/mL bacterial endotoxins (LAL test)

matriz

Durapore®

tamaño de poro

0.22 μm pore size

punto de burbuja

≥50 psi (3450 mbar), air with water at 23 °C

Adaptador

3/4 in. inlet connection
19 mm (3/4 in.) inlet/outlet connection (sanitary flange)
(19 mm (3/4 in.) Sanitary Flange Inlet and Outlet)

Descripción general

Device Configuration: Capsule

Envase

Double Easy-Open bag

Nota de preparación

Sterilization Method
Device integrity and retention was maintained after 3 autoclave cycles of 90 minutes at 126 <nbsp/>°C. Devices can withstand a dose ? 40<nbsp/> kGy gamma exposure.
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b)(6), validated based on large volume parenteral specifications as detailed in USP <788> Particulate Matter in Injections.

Nota de análisis

Quantitative retention of 107 CFU/cm2 Brevundimonas diminuta ATCC® 19146 per AST F838 methodology.

Otras notas

Effluent meets the acceptance criteria set forth in USP <788> for large volume parenterals.

Información legal

ATCC is a registered trademark of American Type Culture Collection
Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPAK is a registered trademark of Merck KGaA, Darmstadt, Germany

¿No encuentra el producto adecuado?  

Pruebe nuestro Herramienta de selección de productos.


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico