KEGBG003FF3
Millipore Express® SPG 0.2 µm, Opticap® XL Capsule
Opticap® XL 300, inlet connection diam. 3/4 in., pore size 0.2 μm
Sinónimos:
Gamma Phobic Opticap® XL 300 Express SPG 0.2 sanitary flange
About This Item
Productos recomendados
Materiales
polyethersulfone membrane
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal
Nivel de calidad
esterilidad
irradiated
non-sterile
Compatibilidad de esterilización
gamma compatible
Línea del producto
Opticap® XL 300
Características
hydrophobic
fabricante / nombre comercial
Opticap®
Parámetros
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
4.1 bar max. inlet pressure (60 psi) at 23 °C
4.2 bar max. differential pressure (60 psid) at 25 °C (Forward)
60 psi max. differential pressure (4.1 bar) (continuous)
60 psig max. inlet pressure
técnicas
gas filtration: suitable
Longitud
11.9 cm (4.7 in.)
Diámetro
5.6 cm (2.2 in.)
filtración área
0.048 m2
diám. conexión a entrada
3/4 in.
An entrada a salida
11.9 cm (4.7 in.)
diám. conexión a salida
3/4 in.
impurezas
≤0.25 EU/mL (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
extraíbles gravimétricos
≤3 mg
matriz
Millipore Express® SPG
tamaño de poro
0.2 μm pore size
punto de burbuja
≥1210 mbar (17.5 psig), air with 70/30% IPA/water at 23 °C
Adaptador
1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet sanitary flange
(19 mm (3/4 in.) Sanitary Flange Inlet and Outlet)
Condiciones de envío
ambient
¿Está buscando productos similares? Visita Guía de comparación de productos
Descripción general
Envase
Otras notas
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Nota de preparación
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Nota de análisis
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After gamma irradiation and three autoclave cycles, the TOC was measured to be equal to or less than 3367 µg/device.
Información legal
Cláusula de descargo de responsabilidad
¿No encuentra el producto adecuado?
Pruebe nuestro Herramienta de selección de productos.
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico