HADK2MAG-61K
MILLIPLEX® Human Adipokine Magnetic Bead Panel 2 - Endocrine Multiplex Assay
The Human Adipokine Magnetic Bead Panel 2, using the Luminex xMAP technology, enables the simultaneous analysis of nine protein biomarkers in human serum and plasma samples.
About This Item
Productos recomendados
Nivel de calidad
reactividad de especies
human
fabricante / nombre comercial
Milliplex®
assay range
accuracy: 87%
(IL-8)
accuracy: 91%
(TNFα)
accuracy: 94%
(Insulin)
standard curve range: 0.64-10,000 pg/mL
(IL-8)
standard curve range: 0.64-10,000 pg/mL
(NGF)
standard curve range: 0.64-10,000 pg/mL
(TNF-α)
standard curve range: 0.96-15,000 pg/mL
(IL-6)
standard curve range: 1.3-20,000 pg/mL
(IL-1β)
standard curve range: 1.3-20,000 pg/mL
(MCP-1)
standard curve range: 38-600,000 pg/mL
(Leptin)
standard curve range: 9.6-150,000 pg/mL
(HGF)
standard curve range: 9.6-150,000 pg/mL
(Insulin)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-1β)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-8)
inter-assay cv: <15%
intra-assay cv: <10%
(Insulin)
inter-assay cv: <15%
intra-assay cv: <10%
(Leptin)
inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1)
inter-assay cv: <15%
intra-assay cv: <10%
(NGF)
inter-assay cv: <20%
intra-assay cv: <10%
(TNFα)
técnicas
multiplexing: suitable
método de detección
fluorometric (Luminex xMAP)
Condiciones de envío
wet ice
Descripción general
The MILLIPLEX® Human Adipokine Panel 2 is a 9-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum or plasma samples: HGF, IL-1β, IL-6, IL-8, Insulin, Leptin, MCP-1, NGF and TNF-α. This kit uses a 96-well format, contains a lyophilized standard cocktail, 2 quality controls and can measure up to 38 samples in duplicate.
Panel Type: Metabolism
Especificidad
Each antibody pair in a panel is highly specific and displays insignificant cross-reactivity to other analytes in the panel.
Aplicación
- Analytes: IL-1β, IL-6, IL-8, Insulin, Leptin, MCP-1, NGF, TNF-α
- Recommended Sample Type: Human serum and plasma
- Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Endocrine
Características y beneficios
Envase
Almacenamiento y estabilidad
Otras notas
Información legal
Cláusula de descargo de responsabilidad
Palabra de señalización
Danger
Frases de peligro
Consejos de prudencia
Clasificaciones de peligro
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Código de clase de almacenamiento
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Contenido relacionado
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico