Key Documents

CTGR03TP1

Millipore

Aervent® 0,2 µm, cartucho

pore size 0.2 μm, cartridge nominal length 30 in. (76 cm), Code 0 (2-222; O-rings)

Sinónimos:

Aervent CTGR Cartridge Filter 30 in. 0.2 µm Code 0

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
23151806
eCl@ss:
32031690

Materiales

PTFE
polypropylene
polypropylene support
silicone seal

Nivel de calidad

esterilidad

non-sterile

Compatibilidad de esterilización

steam-in-place compatible

Línea del producto

Aervent®

Características

hydrophobic

fabricante / nombre comercial

Aervent®

Parámetros

≤72 mL/min nitrogen diffusion at 970 mbar (14 psig) and 23 °C (in 70/30% IPA/water)
1.7 bar max. inlet pressure (25 psi) at 80 °C
1.8 bar max. differential pressure (25 psid) at 80 °C (Forward)
4.1 bar max. differential pressure (60 psid) (Reverse; intermittent)
4.1 bar max. inlet pressure (60 psi) (Reverse; Intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)

técnicas

gas filtration: suitable

Longitud

30 in.

Anchura

2.7 in.

longitud nominal del cartucho

30 in. (76 cm)

Diámetro

6.9 cm (2.7 in.)

filtración área

1.95 m2

impurezas

<0.25 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction)

extraíbles gravimétricos

≤105 mg/cartridge

matriz

Aervent®

tamaño de poro

0.2 μm pore size

entrada

sample type gas

punto de burbuja

≥1100 mbar (16 psig), nitrogen with 70/30% IPA/water at 23 °C

código del cartucho

Code 0 (2-222; O-rings)

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Device Configuration: Cartridge

Características y beneficios

Rated for aerosol retention of a total challenge of 108–1010 plaque forming units of ΦX-174 virus particles at 85 Nm3/h (50 SCFM) per cartridge.

Envase

Double Easy-Open bag

Calidad

Retains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²

Nota de preparación

Sterilization Method
150 (100 forward/50 reverse) SIP cycles of 30 min @ 145 °C
This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Nota de análisis

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: after 24 hours in a 70/30% IPA/water mixture at controlled room temperature
HydroCorr: ≤2.3 mL/min @ 2.6 bar (38 psig) per 30 in cartridge

Otras notas

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Información legal

AERVENT is a registered trademark of Merck KGaA, Darmstadt, Germany
ASTM is a registered trademark of American Society for Testing and Materials

¿No encuentra el producto adecuado?  

Pruebe nuestro Herramienta de selección de productos.


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico