Saltar al contenido
Merck
Todas las fotos(1)

Key Documents

17-10226

Sigma-Aldrich

LentiBrite PSD95-RFP Lentiviral Biosensor

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
12352207
eCl@ss:
34360190

fabricante / nombre comercial

Chemicon®
LentiBrite

Nivel de calidad

técnicas

cell based assay: suitable
immunocytochemistry: suitable
immunofluorescence: suitable
single cell analysis: suitable
transfection: suitable

Nº de acceso UniProt

método de detección

fluorometric

Condiciones de envío

dry ice

Categorías relacionadas

Descripción general

Read our application note in Nature Methods!
http://www.nature.com/app_notes/nmeth/2012/121007/pdf/an8620.pdf
(Click Here!)

Learn more about the advantages of our LentiBrite Lentiviral Biosensors! Click Here

Biosensors can be used to detect the presence/absence of a particular protein as well as the subcellular location of that protein within the live state of a cell. Fluorescent tags are often desired as a means to visualize the protein of interest within a cell by either fluorescent microscopy or time-lapse video capture. Visualizing live cells without disruption allows researchers to observe cellular conditions in real time.

Lentiviral vector systems are a popular research tool used to introduce gene products into cells. Lentiviral transfection has advantages over non-viral methods such as chemical-based transfection including higher-efficiency transfection of dividing and non-dividing cells, long-term stable expression of the transgene, and low immunogenicity.

EMD Millipore is introducing LentiBrite Lentiviral Biosensors, a new suite of pre-packaged lentiviral particles encoding important and foundational proteins of autophagy, apoptosis, and cell structure for visualization under different cell/disease states in live cell and in vitro analysis.
  • Pre-packaged, fluorescently-tagged with GFP & RFP
  • Higher efficiency transfection as compared to traditional chemical-based and other non-viral-based transfection methods
  • Ability to transfect dividing, non-dividing, and difficult-to-transfect cell types, such as primary cells or stem cells
  • Non-disruptive towards cellular function

EMD Millipore’s LentiBrite PSD-95-RFP lentiviral particles provide bright fluorescence and precise localization to enable live cell analysis of PSD dynamics in neuronal cells.
The postsynaptic side of an excitatory synapse contains an electron- and protein-dense region, the postsynaptic density (PSD), that positions neurotransmitters adjacent to sites of presynaptic neurotransmitter release, and also concentrates signaling molecules. MAGUKs (membrane-associated guanylate kinases) serve both as central organizers of the PSD and as signaling molecules. One such MAGUK, PSD-95, is associated with the dendritic spines of mature synapses, and is relatively immobile compared to other MAGUKs. PSD-95 fused to fluorescent proteins has been employed to quantify turnover and mobility of PSD-95.
EMD Millipore’s LentiBrite PSD-95-RFP lentiviral particles provide bright fluorescence and precise localization to enable live cell analysis of PSD dynamics in neuronal cells.

Aplicación

Fluorescence Microscopy Imaging:
Primary rat hippocampal neuron cells were plated in a poly-D-lysine coated chambered cover glass for 5 days and transduced with lentiviral particles at an MOI of 20 for 24 hours. After media replacement and 2 weeks further incubation, cells were imaged live by oil immersion wide-field fluorescence microscopy. The PSD95-RFP displays a dotted distribution along the neuritis.

For optimal fluorescent visualization, it is recommended to analyze the target expression level within 24-48 hrs after transfection/infection for optimal live cell analysis, as fluorescent intensity may dim over time, especially in difficult-to-transfect cell lines. Infected cells may be frozen down after successful transfection/infection and thawed in culture to retain positive fluorescent expression beyond 24-48 hrs. Length and intensity of fluorescent expression varies between cell lines. Higher MOIs may be required for difficult-to-transfect cell lines.
Research Category
Neuroscience
Research Sub Category
Synapse & Synaptic Biology

Componentes

TagPSD95-RFP Lentivirus:
One vial containing 25 µL of lentiviral particles at a minimum of 3 x 10E8 infectious units (IFU) per mL. For lot-specific titer information, please see “Viral Titer” in the datasheet.


Promoter
EF-1 (Elongation Factor-1)

Multiplicty of Infection (MOI)
MOI = Ratio of # of infectious lentiviral particles (IFU) to # of cells being infected.
Typical MOI values for neurons to achieve high transduction efficiency and signal intensity are in the range of 20-40. For this target, some neuronal cell types may require higher or lower MOIs.
NOTE: MOI should be titrated and optimized by the end user for each cell type and lentiviral target to achieve desired transduction efficiency and signal intensity.

Calidad

Evaluated by transduction of HT-1080 cells and fluorescent imaging performed for assessment of transduction efficiency.

Forma física

PEG precipitation

Almacenamiento y estabilidad

Storage and Handling
Lentivirus is stable for at least 4 months from date of receipt when stored at -80°C. After first thaw, place immediately on ice and freeze in working aliquots at -80°C. Frozen aliquots may be stored for at least 2 months. Further freeze/thaws may result in decreased virus titer and transduction efficiency.

IMPORTANT SAFETY NOTE
Replication-defective lentiviral vectors, such as the 3rd Generation vector provided in this product, are not known to cause any diseases in humans or animals. However, lentiviruses can integrate into the host cell genome and thus pose some risk of insertional mutagenesis. Material is a Risk Group 2 and should be handled under BSL2 controls. A detailed discussion of biosafety of lentiviral vectors is provided in Pauwels, K. et al. (2009). State-of-the-art lentiviral vectors for research use: Risk assessment and biosafety recommendations. Curr. Gene Ther. 9: 459-474.

Información legal

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Código de clase de almacenamiento

10 - Combustible liquids

Clase de riesgo para el agua (WGK)

WGK 2


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico