MT17MAG47PMX25BK
MILLIPLEX® Mouse TH17 Magnetic Bead Panel - Premixed 25 plex Space Saver (Bulk) Packaging
Inflammation/Immunology Bead-Based Multiplex Assays using the Luminex technology enables the simultaneous analysis of multiple cytokine and chemokine Th17 biomarkers in mouse serum, plasma and cell culture samples.
Synonym(s):
Magnetic Bead Panel, Mouse TH17 Panel, TH17 Magnetic Bead Panel
About This Item
Quality Level
species reactivity
human
manufacturer/tradename
Milliplex®
assay range
linearity: 111.0%
(1:04)
linearity: 113.1%
(1:08)
standard curve range: 1.5-1,500 pg/mL
(IL-4)
standard curve range: 10-10,000 pg/mL
(IL-17F)
standard curve range: 127-130,000 pg/mL
(IL-28B)
standard curve range: 15-15,000 pg/mL
(IL-1β)
standard curve range: 2.4-2,500 pg/mL
(IL-22)
standard curve range: 20-20,000 pg/mL
(IL-10, IL-12(p70), & IL-21)
standard curve range: 3.4-3,500 pg/mL
(TNFα)
standard curve range: 34-35,000 pg/mL
(GM-CSF & IL-15)
standard curve range: 342-350,000 pg/mL
(IL-23)
standard curve range: 39-40,000 pg/mL
(IL-13 & IL-17A)
standard curve range: 4.9-5,000 pg/mL
(IL-5)
standard curve range: 488-500,000 pg/mL
(TNFβ)
standard curve range: 49-50,000 pg/mL
(CD40L IL-31 & MIP-3α)
standard curve range: 586-600,000 pg/mL
(IL-17E/ IL-25)
standard curve range: 6.9-6,000 pg/mL
(IL-2)
standard curve range: 7.8-8,000 pg/mL
(IFNγ & IL-6)
standard curve range: 78-80,000 pg/mL
(IL-33)
standard curve range: 879-900,000 pg/mL
(IL-27)
technique(s)
multiplexing: suitable
compatibility
configured for Premixed
detection method
fluorometric (Luminex xMAP)
shipped in
wet ice
General description
Panel Type: Cytokines/Chemokines
Specificity
There was no or minimum cross-reactivity between the antibodies and any other analytes in the panel (see details in assay protocol).
Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.
Application
- Analytes: CD40 Ligand, GM-CSF, IFN-γ, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-10, IL-12 (p70), IL-13, IL-15, IL-17A, IL-17E/IL-25, IL-17F, IL-21, IL-22, IL-23, IL-27, IL-28B, IL-31, IL-33, MIP-3α/CCL20, TNF-α, TNFβ
- Recommended Sample type: serum, plasma or tissue/cell lysate and culture supernatant
- Recommended Sample dilution: neat
- Assay Run Time: overnight or one day
- Research Category: Inflammation & Immunology
Storage and Stability
Other Notes
Legal Information
Disclaimer
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service