Direkt zum Inhalt
Merck

GC Analysis of Phthalate Esters in Corn Oil (Spiked) on SLB®-5ms after SPME with a 100 μm PDMS Fiber

GC Analysis of Phthalate Esters in Corn Oil (Spiked) on SLB®-5ms after SPME with a 100 μm PDMS Fiber suitable for GC, application for SPME

Materialien

Analytische Säule

Produkt-Nr.
Beschreibung
Preisangaben

SLB®-5ms GC-Kapillarsäule

L × I.D. 20 m × 0.18 mm, df 0.18 μm

SPME-Faser

Produkt-Nr.
Beschreibung
Preisangaben

SPME-Faseranordnung Polydimethylsiloxan (PDMS)

df 7 μm(PDMS, needle size 24 ga, for use with manual holder

SPME-Faseranordnung Polydimethylsiloxan (PDMS)

df 100 μm(PDMS, for use with autosampler, needle size 23 ga

SPME-Faseranordnung Polydimethylsiloxan (PDMS)

df 100 μm(PDMS, needle size 24 ga, for use with manual holder

Standard

Produkt-Nr.
Beschreibung
Preisangaben

Diphenylphthalat

PESTANAL®, analytical standard

Dicyclohexylphthalat

PESTANAL®, analytical standard

Phthalsäure-bis-methylglykolester

analytical standard

Dimethylphthalat -Lösung

certified reference material, 5000 μg/mL in methanol

Phthalsäure-bis-2-ethylhexylester

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Phthalsäuredibutylester

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Diisobutylphthalat

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Ähnliches Produkt

Produkt-Nr.
Beschreibung
Preisangaben

Fläschchen, Schraubgewinde, Klarglas (nur Fläschchen)

volume 15 mL, clear glass vial, thread for 18-400, pkg of 100 ea

Screw cap, polypropylene, with open center

black phenolic hole cap, for use with 15 mL vial with 18-400 thread, pkg of 100 ea

Septa, tan PTFE/Silikon

white tan PTFE/silicone, diam. × thickness 16 mm × 0.090 in., for use with 15 mL vial, pkg of 100 ea

SPME-Faserhalter

for use with Manual Sampling

SPME-Faserhalter

for use with CTC CombiPAL, Gerstel MPS2

CONDITIONS

sample/matrix

corn oil spiked with phthalate esters at 500 μg/kg

SPME fiber

100 μm PDMS (57300-U)

extraction

headspace, 95 °C (measured in headspace)

desorption process

260 °C for 4 min

column

F.S. CAP. SLB-5ms 20 m x 0.18 mm I.D., 0.18 μm (28564-U)

oven

60 °C (1 min), 10 °C/min to 330 °C (10 min)

inj. temp.

260 °C

carrier gas

helium, 0.6 mL/min, constant

liner

0.75 mm I.D. SPME

sample

Corn oil

Beschreibung

Hinweis zur Analyse

In this application, SPME was used for the analysis of phthalate esters from oily samples, specifically the oil-based flavor packets included with ramen noodle kits. Spiked samples of corn oil and flavored oils included with ramen noodle kits were analyzed using high temperature SPME headspace extraction using a 100 μm PDMS fiber which was then directly desorbed into the GC/MS system. Calibration standards were prepared in corn oil, and spiked samples of chicken and beef oil-based flavors were analyzed. The SLB-5ms GC columns provide consistently low-bleed, inert, efficient, and durable separations.

Rechtliche Hinweise

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany