Direkt zum Inhalt
Merck

KPHLA02TH3

Millipore

Durapore® 0,45 µm, Opticap®-XL-Kapsel

Opticap® XL 2, inlet connection diam. 1.5 in., cartridge nominal length 2 in. (5 cm)

Synonym(e):

Opticap XL2 Durapore 0.45 μm without prefilter TC/HB

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806

Materialien

PVDF
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal

Qualitätsniveau

Einhaltung gesetzlicher Vorschriften

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Sterilität

non-sterile

Kompatibilität mit Sterilisationsverfahren

autoclavable compatible

Produktlinie

Opticap® XL 2

Leistungsmerkmale

hydrophilic

Hersteller/Markenname

Opticap®

Parameter

1.0 bar max. inlet pressure (15 psi) at 80 °C
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.4 bar max. differential pressure (50 psid) at 25 °C (Forward)
3.4 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure

Methode(n)

bioburden reduction: suitable

Länge

14.2 cm (5.6 in.)

Breite

3.3 in.

Nennlänge Kartusche

2 in. (5 cm)

Durchmesser

8.4 cm (3.3 in.)

Filtrationsfläche

0.09 m2

Durchm. Einlassanschluss

1.5 in.

Breite Einlass bis Auslass

14.2 cm (5.6 in.)

Durchm. Auslassanschluss

9/16 in.

Verunreinigungen

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Gravimetrisch bestimmte extrahierbare Substanzen

≤10 mg/capsule

Matrix

Durapore®

Porengröße

0.45 μm

Aufnahme

sample type liquid

Blasenpunkt

≥1930 mbar (28 psig), air with water at 23 °C

Fitting

1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet sanitary flange
outlet hose barb
(38 mm (1 1/2 in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet)

Allgemeine Beschreibung

Device Configuration: Filtereinheit

Verpackung

Leicht zu öffnender Doppelbeutel

Sonstige Hinweise

Diese Produkte werden in einem Werk hergestellt, das den GMP-Richtlinien der FDA entspricht.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Angaben zur Herstellung

Sterilization Method
3 Autoklavenzyklen von 60 min bei 126 °C; nicht inline dampfsterilisierbar
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Hinweis zur Analyse

Erfüllt die Anforderungen des USP-Tests auf oxidierbare Substanzen nach Durchspülen mit ≥500 ml Wasser
Gravimetric Extractables: after 24 hours in water at controlled room temperature

Rechtliche Hinweise

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Haftungsausschluss

EMD Millipore Corporation bestätigt, dass dieses Produkt der europäischen Druckgeräterichtlinie 97/23/EG vom 29. Mai 1997 entspricht. Dieses Produkt wurde unter Artikel 3 § 3 der Druckgeräterichtlinie klassifiziert. Das Produkt wurde in Übereinstimmung mit anerkannten technischen Methoden entwickelt und hergestellt, um einen sicheren Betrieb zu gewährleisten. In Konformität mit Artikel 3 § 3 dieser Druckgeräterichtlinie besitzt dieses Produkt kein CE-Zeichen.

Sie haben nicht das passende Produkt gefunden?  

Probieren Sie unser Produkt-Auswahlhilfe. aus.


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.