Direkt zum Inhalt
Merck
Alle Fotos(1)

Dokumente

EZBRAIN-SET

Millipore

Human Amyloid β40 and Amyloid β42 ELISA Kit

measures Amyloid β40 and Amyloid β42 in 50 μL tissue or cell lysate; combo pack

Synonym(e):

Amyloid β40/β42 ELISA, Brain ELISA Kit, Human Brain Amyloid ELISA

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
12161503
NACRES:
NA.84

product name

Human Amyloid β40 and Amyloid β42 Brain ELISA,

Speziesreaktivität

human

Qualitätsniveau

Verpackung

kit of 2 × 96 wells

Parameter

50 μL sample volume (Overnight assay)

assay range

sensitivity: 6.0 pg/mL
(The lowest level of Amyloid β1-40 standard used in this assay ; 50 μL sample size)

sensitivity: 8 pg/mL
(The lowest level of Amyloid ß1-42 standard used in this assay; 50 μL sample size)

inter-assay cv: <10
intra-assay cv: <10
standard curve range: 16-500 pg/mL

Methode(n)

ELISA: suitable

Aufnahme

sample type tissue/cellular lysate

Anwendung(en)

research use

Nachweisverfahren

colorimetric (450nm/590nm)

Versandbedingung

wet ice

Lagertemp.

2-8°C

Angaben zum Gen

human ... APP(351)

Spezifität

The Amyloid β40 ELISA uses monoclonal anti-Aβ antibodies with high selectivity for human Aβ. The capture antibody recognizes the C-terminal end of Amyloid β1-40, which causes a high selectivity for Aβ 40. The cross-reactivity of the used antibodies to other Amyloid peptides was tested by ELISA and BIACORE and shows no significant cross-reactivity to Aβ1-38, Aβ1-39, Aβ1-42, Aβ1-43 and Aβ1-44. The Amyloid β42 ELISA uses monoclonal anti-Aβ antibodies with high selectivity for human Aβ. The capture antibody recognizes the C-terminal end of Amyloid β1-42, which causes a high selectivity for Aβ42. The cross-reactivity of the used antibodies to other Amyloid peptides was tested by ELISA and BIACORE and shows no significant cross-reactivity to Aβ1-38, Aβ1-39, Aβ1-42, Aβ1-43 and Aβ1-44.


Used to detect/quantify: Amyloid β40 & Amyloid β42

Anwendung

These assays require 50 µl of sample and are overnight assays.

Verpackung

96-well plate

Lagerung und Haltbarkeit

Components in the kit can be stored up to 2 weeks at 2-8°C

Sonstige Hinweise

Contact technical support for information

Haftungsausschluss

For research use only. Not for use in diagnostic procedures.

Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.