1.51015
TLC aluminum sheets, silica gel 60 RP-18 F254s MS-grade
pkg of 20 sheets, sheet L × W 5 cm × 7.5 cm, aluminum support
Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise
Alle Fotos(1)
About This Item
Empfohlene Produkte
Materialien
aluminum support
silica gel 60 matrix
Qualitätsniveau
Leistungsmerkmale
binder Organic Polymer
fluorescent indicator
Verpackung
pkg of 20 sheets
Methode(n)
TLC-MS: suitable
thin layer chromatography (TLC): suitable
Schichtdicke
100 μm
Blatt L × B
5 cm × 7.5 cm
Partikelgröße
10-12 μm
Porengröße
60 Å medium pore diameter
Lagertemp.
2-30°C
Allgemeine Beschreibung
20 Aluminium sheets 5x7.5
Reference:
Gertrud Morlock, Wolfgang Schwack
Coupling of planar chromatography to mass spectrometry
TrAC Trends in Analytical Chemistry, Volume 29, Issue 10, 2010, Pages 1157-1171
Gertrud Morlock, Wolfgang Schwack
Coupling of planar chromatography to mass spectrometry
TrAC Trends in Analytical Chemistry, Volume 29, Issue 10, 2010, Pages 1157-1171
Hinweis zur Analyse
Specific surface area(according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume(N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution):9.7 - 11.7 µm
Layerthickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
A) Cholesterin test
hRf-values
- cholesterin: 35 - 43
B) Steroid test
- methyltestosterone: 14 - 24
- Reichstein S: 28 - 38- hydrocortisone: 40 - 50
Typical value determined on an activated sheet (120°C, 15 min)
Eluent A) aceton/ water (95/5 v/v)
Eluent B) aceton/ water (60/40 v/v)
C) MS suitability test
- Angiotensin II (signal-to-noiseratio 50ng): ≥ 25
measured with 5000 shots
- Caffeine (signal-to-ratio 5ng): ≥25
Pore volume(N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution):9.7 - 11.7 µm
Layerthickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
A) Cholesterin test
hRf-values
- cholesterin: 35 - 43
B) Steroid test
- methyltestosterone: 14 - 24
- Reichstein S: 28 - 38- hydrocortisone: 40 - 50
Typical value determined on an activated sheet (120°C, 15 min)
Eluent A) aceton/ water (95/5 v/v)
Eluent B) aceton/ water (60/40 v/v)
C) MS suitability test
- Angiotensin II (signal-to-noiseratio 50ng): ≥ 25
measured with 5000 shots
- Caffeine (signal-to-ratio 5ng): ≥25
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.