Direkt zum Inhalt
Merck

487112

Supelco

Ethylbenzol -Lösung

NMR reference standard, 0.1% in chloroform-d (99.8 atom % D), TMS 0.01 %, NMR tube size 3 mm × 8 in.

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
C8H10
CAS-Nummer:
Molekulargewicht:
106.17
MDL-Nummer:
UNSPSC-Code:
12142201
PubChem Substanz-ID:
NACRES:
NA.24

Qualität

NMR reference standard
analytical standard

Zusammensetzung

TMS, 0.01%

Konzentration

0.1% in chloroform-d (99.8 atom % D)

Methode(n)

NMR: suitable

NMR-Röhrchengröße

3 mm × 8 in.

Anwendung(en)

environmental

Format

single component solution

SMILES String

CCc1ccccc1

InChI

1S/C8H10/c1-2-8-6-4-3-5-7-8/h3-7H,2H2,1H3

InChIKey

YNQLUTRBYVCPMQ-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Leistungsmerkmale und Vorteile

1H-Empfindlichkeit

Menge

3 mm O.D. tube contains 0.235 mL.

Piktogramme

Skull and crossbonesHealth hazard

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Carc. 2 - Eye Irrit. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 Oral - STOT SE 3

Zielorgane

Central nervous system, Liver,Kidney

Lagerklassenschlüssel

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Rogers Ribeiro et al.
Biodegradation, 24(2), 269-278 (2012-08-23)
Because benzene, toluene, ethylbenzene, and xylenes (BTEX) and ethanol are important contaminants present in Brazilian gasoline, it is essential to develop technology that can be used in the bioremediation of gasoline-contaminated aquifers. This paper evaluates the performance of a horizontal-flow
João Carlos Fraga da Rosa et al.
Environmental monitoring and assessment, 185(7), 5883-5890 (2012-11-10)
The gas station attendants are exposed daily to chemical agents that compose gasoline, such as BTEX (benzene, toluene, ethylbenzene, and xylene), and the exposure to these agents can cause a variety of effects on the human health. Among the various
T Tunsaringkarn et al.
The international journal of occupational and environmental medicine, 3(3), 117-125 (2012-10-02)
Gasoline station workers are exposed to volatile organic compounds such as benzene, toluene, ethylbenzene and xylene (BTEX). To determine the level of exposure to BTEX compounds among gasoline station workers and measure the roadside concentrations of these compounds in the
Carla G A da Silva et al.
Journal of chromatography. A, 1260, 81-87 (2012-09-12)
Endcapped stationary phases were prepared after thermal immobilization of poly(methyloctadecylsiloxane) (PMODS) onto zirconized and titanized silica supports. These new stationary phases have lower densities of residual hydroxyl groups, according to infrared spectroscopy and 29Si CP-MAS NMR and as shown by
Dânia Elisa Christofoletti Mazzeo et al.
Chemosphere, 90(3), 1030-1036 (2012-09-18)
The BTEX (benzene, toluene, ethylbenzene and xylene) mixture is an environmental pollutant that has a high potential to contaminate water resources, especially groundwater. The bioremediation process by microorganisms has often been used as a tool for removing BTEX from contaminated

Artikel

Sigma-Aldrich.com provides an informational article regarding the use of stable, labeled isotopes as NMR reference standards.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.