Direkt zum Inhalt
Merck

143634

Sigma-Aldrich

p-Tolylisocyanat

99%

Synonym(e):

4-Methylphenyl-isocyanat

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
CH3C6H4NCO
CAS-Nummer:
Molekulargewicht:
133.15
Beilstein:
471494
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12352100
PubChem Substanz-ID:
NACRES:
NA.22

Assay

99%

Form

liquid

Brechungsindex

n20/D 1.531 (lit.)

bp

70-72 °C/10 mmHg (lit.)

Dichte

1.056 g/mL at 25 °C (lit.)

Lagertemp.

2-8°C

SMILES String

Cc1ccc(cc1)N=C=O

InChI

1S/C8H7NO/c1-7-2-4-8(5-3-7)9-6-10/h2-5H,1H3

InChIKey

MGYGFNQQGAQEON-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

p-Tolyl isocyanate reacts with human serum albumin to form antigen which helps in detecting IgE antibodies in workers hypersensitive to toluene diisocyanate.

Anwendung

p-Tolyl isocyanate was used to study the catalytic role of supported Rhodium(I) complex toward the reductive carbonylation of nitrobenzene in DMF medium.

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Dam. 1 - Resp. Sens. 1 - Skin Corr. 1C - Skin Sens. 1 - STOT SE 3

Zielorgane

Respiratory system

Lagerklassenschlüssel

8A - Combustible corrosive hazardous materials

WGK

WGK 3

Flammpunkt (°F)

150.8 °F - closed cup

Flammpunkt (°C)

66 °C - closed cup

Persönliche Schutzausrüstung

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

J M Danks et al.
Clinical allergy, 11(2), 161-168 (1981-03-01)
Radioallergosorbent testing was used to look for the presence of specific IgE antibody against a para-tolyl-mono-isocyanate human serum albumin conjugate in sera from five groups of subjects. The first three groups consisted of individuals exposed to toluene diisocyanate (TDI) who
B T Butcher et al.
The Journal of allergy and clinical immunology, 70(4), 231-235 (1982-10-01)
Toluene diisocyanate (TDI) sensitivity accompanied by nonspecific bronchial hyperresponsiveness occurs in approximately 5% of occupationally exposed workers. We report the case of a 32-yr-old worker followed longitudinally after removal from isocyanate exposure. TDI reactivity was lost 11 mo after removal
C J Game
American Industrial Hygiene Association journal, 43(10), 759-763 (1982-10-01)
Sera of 91 people were assayed for IgE which bound to a p-tolyl-isocyanate-human serum albumin conjugate. The sera came from 20 blood donors, 70 factory workers, and 1 casualty patient. Three factory workers had abnormally high assay values in association
B T Butcher et al.
Clinical allergy, 13(1), 31-34 (1983-01-01)
Sera from 149 occupationally exposed toluene diisocyanate (TDI) workers were tested by RAST with p-tolyl monoisocyanate human serum albumin (TMI-HSA). Of the seven positives, one had a history suggestive of TDI asthma and one had a rash which may have
K C Chang et al.
Clinical allergy, 14(4), 329-339 (1984-07-01)
A worker developed two episodes of severe asthma 90 min after cutting a polyurethane plate made of diphenylmethane diisocyanate (MDI) using a rapidly turning carbide blade. Intradermal skin testing with MDI-human serum albumin (MDI-HSA) and p-tolyl isocyanate-HSA (p-TMI-HSA) were positive

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.