Accéder au contenu
Merck
  • The Inhibition of Maillard Browning by Different Concentrations of Rosmarinic Acid and Epigallocatechin-3-Gallate in Model, Bakery, and Fruit Systems.

The Inhibition of Maillard Browning by Different Concentrations of Rosmarinic Acid and Epigallocatechin-3-Gallate in Model, Bakery, and Fruit Systems.

Journal of food science (2015-09-27)
Nicole Favreau-Farhadi, Lauren Pecukonis, Ann Barrett
RÉSUMÉ

Rosmarinic acid and Epigallocatechin gallate concentrations were studied as natural inhibitors of Maillard browning in glucose/glycine model systems, and in bakery rolls and applesauce. The concentrations of the inhibitors were varied to determine the highest level of inhibition without a pro-oxidant/browning effect. UV absorbance and gas chromatography/mass spec (GC/MS) with solid phase microextraction (SPME) sampling was used to study browning in the model systems. Hunter L*, a*, b* was used to analyze the color change results of the inhibitors on applesauce and bakery rolls. It was determined that a 1.0% solution of either antioxidant in the glucose/glycine system produced the greatest inhibition and a synergistic effect was not apparent when the two were combined. Inhibition of browning and a lack of synergy between the antioxidants were also determined in food systems consisting of applesauce and bakery rolls. GC/MS analysis of the model system revealed a high level of pyrazine formation in no-inhibitor control samples and the absence of pyrazines in inhibitor-containing samples. Natural browning inhibitors, that is Rosmarinic acid and Epigallocatechin gallate, can be added to food items to inhibit browning over a prolonged period of storage in order to increase product shelf stability. The concentrations of the inhibitors require optimization since a pro-oxidant effect and increased browning will occur at high levels.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Glycérol, ACS reagent, ≥99.5%
Sigma-Aldrich
Glycérol, for molecular biology, ≥99.0%
Sigma-Aldrich
Glycérol, ReagentPlus®, ≥99.0% (GC)
Sigma-Aldrich
Glycine, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
Glycine, suitable for electrophoresis, ≥99%
Sigma-Aldrich
Glycine, BioUltra, for molecular biology, ≥99.0% (NT)
Sigma-Aldrich
Glycérol solution, 83.5-89.5% (T)
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Sigma-Aldrich
Azoture de sodium, BioUltra, ≥99.5% (T)
Sigma-Aldrich
Glycine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, ≥98.5%
Sigma-Aldrich
Glycérol, BioUltra, for molecular biology, anhydrous, ≥99.5% (GC)
Sigma-Aldrich
Glycérol, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for electrophoresis, ≥99% (GC)
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Sigma-Aldrich
Azoture de sodium, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Glycérol, puriss., anhydrous, 99.0-101.0% (alkalimetric)
SAFC
Glycine
Sigma-Aldrich
(−)-Epigallocatechin gallate, ≥95%
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Sigma-Aldrich
Azoture de sodium, purum p.a., ≥99.0% (T)
Sigma-Aldrich
Glycérol, FCC, FG
Sigma-Aldrich
Glycérol, puriss. p.a., ACS reagent, anhydrous, dist., ≥99.5% (GC)
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Sigma-Aldrich
Glycérol, ≥99.5%
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Sigma-Aldrich
Pyrazine, ≥99%
Sigma-Aldrich
(−)-Epigallocatechin gallate, ≥80% (HPLC), from green tea
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga