GE17-5481-15

HiScreen Capto Core 700

Cytiva 17-5481-15, pkg of 1 column

Synonyme(s) :

Capto Core 700 Column

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
23151817
Nomenclature NACRES :
NA.56

ligand

octylamine

Conditionnement

pkg of 1 column

Fabricant/nom de marque

Cytiva 17-5481-15

Paramètres

0.8-3.9 ml/min flow rate
8 bar

Taille du lit

77 mm × 100 mm

Volume du lit

4.7 mL

D.I. de la colonne

7.7 mm

Matrice

highly cross-linked agarose

Taille moy. des particules

75 (d₅₀v is the median particle size of the cumulative volume distribution)

cleaning

3-13(pH interval where the medium can be subjected to, for cleaning- or sanitization-in-place.)

working range

2-14(pH interval where the medium can be operated without significant change in function.)

Capacité

~13 mg binding capacity (ovalbumin)

Adéquation

suitable for bioprocess medium

Description générale

Capto Core 700 is designed for intermediate purification and polishing of viruses and other large biomolecules. The novel core bead technology and multimodal, octylamine ligand give Capto Core 700 dual functionality, size exclusion, and binding chromatography in one chromatography resin.

Capto Core 700 is composed of a ligand-activated core and inactive shell. The inactive shell excludes large molecules (cut off ~ Mr 700 000 [700 kDa]) from entering the core through the pores of the shell. These larger molecules are collected in the column flowthrough while smaller impurities bind to the internalized ligands. The core of each bead is functionalized with ligands that are both hydrophobic and positively charged, resulting in a highly efficient multimodal binding of various contaminants small enough to enter the core. The multimodal ligands ensure strong binding with most impurities over a wide range of pH and salt concentrations. Bound impurities are removed from the beads by cleaning-in-place (CIP) procedures using NaOH and in most cases, a solvent.
Dynamic binding capacities were measured at 10% breakthrough with a residence time of 3 min (1.6 ml/min = 200 cm/h) in HiScreen columns. Buffer: 20 mM Tris-HCl, 150 mM NaCl, pH 7.5.

Caractéristiques et avantages

  • For intermediate purification and polishing of viruses and other large biomolecules (Mr > 700 000) in flowthrough mode.
  • Novel core bead technology allows efficient capture of contaminants while target molecules are collected in the flowthrough.
  • Significantly improved productivity and higher flow rates compared with gel filtration methods.
  • Straightforward optimization due to flowthrough chromatography and robust performance.
  • Convenient small-scale purification, process development, and scale-up using prepacked HiTrap and HiScreen columns.

Stockage et stabilité

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol)

Remarque sur l'analyse

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Informations légales

Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva

Produit(s) apparenté(s)

Pictogrammes

Flame

Mention d'avertissement

Warning

Mentions de danger

Code de la classe de stockage

3 - Flammable liquids


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique