1.50441
SeQuant™ ZIC®-HILIC 100Å (3.5 µm) HPLC Columns
L × I.D. 100 mm x 2.1 mm HPLC Column, PEEK-lined stainless steel
Synonyme(s) :
Zwitterionic Hydrophilic Interaction Liquid Chromatography HPLC Column
About This Item
Produits recommandés
product name
SeQuant™ ZIC-HILIC™ 3,5 µm, 100 Å 100 x 2,1 mm, PEEK-lined stainless steel column, suitable for HPLC
Matériaux
PEEK-lined stainless steel column
Niveau de qualité
Agence
suitable for USP L114
Gamme de produits
SeQuant™
Caractéristiques
endcapped: no
Paramètres
550 bar pressure
70 °C max. temp.
Technique(s)
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)
Colonne, L × D.I.
10 cm × 2.1 mm
Matrice
fully porous particle
Groupe de la matrice active
ZIC-HILIC bonding phase
Taille des particules
3.5 μm
Dimension de pores
100 Å pore size
pH de fonctionnement
2-7.5
Technique de séparation
hydrophilic interaction (HILIC)
Température de stockage
no temp limit
Description générale
Informations légales
Produit(s) apparenté(s)
Code de la classe de stockage
10-13 - German Storage Class 10 to 13
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique