Direkt zum Inhalt
Merck
  • Preparation and application of sol-gel acrylate and methacrylate solid-phase microextraction fibres for gas chromatographic analysis of organoarsenic compounds.

Preparation and application of sol-gel acrylate and methacrylate solid-phase microextraction fibres for gas chromatographic analysis of organoarsenic compounds.

Analytica chimica acta (2014-07-09)
Stanisław Popiel, Jakub Nawała, Krzysztof Czupryński
ZUSAMMENFASSUNG

Novel solid-phase microextraction (SPME) fibres containing methyl, ethyl, butyl acrylate and methacrylate were first prepared by a sol-gel technique and investigated for determination of selected organoarsenic compounds (lewisite, methyldichloroarsine, phenyldichloroarsine, diphenylchloroarsine and triphenylarsine) from water samples. The influence of sorption and desorption temperature and time for extraction efficiency were examined. The best new fibre coatings (methyl acrylate (MA), methyl methacrylate (MMA) and combination of methyl acrylate and methacrylate (MA/MMA)) for analysis of organoarsenic compounds were selected and compared with commercial fibres. The distribution coefficients Kfs were determined for the best novel fibres and for absorption commercial fibres. The highest Kfs value were obtained for MA/MMA and MMA fibres and were respectively 9458 and 6561 for lewisite and 6458 and 5884 for triphenylarsine. The limit of detection and quantification were determined for the three laboratory obtained fibres (MA, MMA and MA/MMA). LODs for tested fibres, at a signal-to-noise of 3, were 0.03-0.3 ng mL(-1). LOQs for selected coatings, at signal-to-noise of 10, were 0.1-0.8 ng mL(-1). The relative standard deviations (RSD) for all measurements were 4.3-6.5% (n=9) and relative errors were 2.5-5%. The laboratory obtained fibres were used for environmental analysis of pore water samples from the Baltic Sea.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
1-Butanol, 99.9%
Sigma-Aldrich
1-Butanol, ACS reagent, ≥99.4%
Sigma-Aldrich
1-Butanol, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Methylmethacrylat, contains ≤30 ppm MEHQ as inhibitor, 99%
Sigma-Aldrich
Divinylbenzol, technical grade, 80%
Sigma-Aldrich
1-Octanol, ACS reagent, ≥99%
Sigma-Aldrich
Butylacrylat, ≥99%, contains 10-60 ppm monomethyl ether hydroquinone as inhibitor
Sigma-Aldrich
1-Butanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.5% (GC)
Sigma-Aldrich
Tetraethylenglycol, 99%
Sigma-Aldrich
1-Octanol, suitable for HPLC, ≥99%
Sigma-Aldrich
Ethylacrylat, contains 10-20 ppm MEHQ as inhibitor, 99%
Sigma-Aldrich
1-Octanol, ReagentPlus®, 99%
Sigma-Aldrich
Methylacrylat, 99%, contains ≤100 ppm monomethyl ether hydroquinone as inhibitor
Sigma-Aldrich
Butylmethacrylat, 99%, contains monomethyl ether hydroquinone as inhibitor
Sigma-Aldrich
1-Butanol, for molecular biology, ≥99%
Sigma-Aldrich
Methylmethacrylat, 99%, stabilized
Sigma-Aldrich
Divinylbenzol, technical grade, 55%
Sigma-Aldrich
Poly(dimethylsiloxan), viscosity 1.0 cSt (25 °C)
Sigma-Aldrich
Dibutylsulfid, ≥98.0% (GC)
Sigma-Aldrich
Butylalkohol, natural, ≥99.5%, FCC, FG
Sigma-Aldrich
Ethylacrylat, ≥99.5%, stabilized
Sigma-Aldrich
Ethylendiamintetraessigsäure Dinatriumsalz -Lösung, 2%, solution
Sigma-Aldrich
Ethylmethacrylat, contains 15-20 ppm monomethyl ether hydroquinone as inhibitor, 99%
Sigma-Aldrich
1-Butanol, anhydrous, 99.8%
Sigma-Aldrich
Ethylendiamintetraessigsäure Dinatriumsalz -Lösung, for molecular biology, 0.5 M in H2O, DNase, RNase, NICKase and protease, none detected
Sigma-Aldrich
Triphenylarsin, 97%
Sigma-Aldrich
1-Octanol, ≥98%, FCC, FG
Sigma-Aldrich
Poly-(dimethylsiloxan), viscosity 0.65 cSt (25 °C)
Sigma-Aldrich
Dibutylsulfid, 96%
Sigma-Aldrich
1-Octanol, anhydrous, ≥99%