GC Analysis of Pesticides in Beef Kidney on SLB®-5ms (20 m x 0.18 mm I.D., 0.36 μm) after QuEChERS Cleanup using Supel Que Z-Sep+, MS in SIM Mode, Fast GC Analysis

suitable for GC, application for SPE

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Methode(n)

gas chromatography (GC): suitable
solid phase extraction (SPE): suitable

Testparameter

sample preparation: Dispersive (QuEChERS)
sample/matrix: 10 gm homogenized beef kidney spiked at 50 ng/g with pesticides
extraction tube: Supel Que Acetate (AC) Tube (55234-U)
extraction process: add 10 mL of acetonitrile; shake for 1 minute; add contents of Supel Que acetate extraction tube (55234-U); shake immediately for 1 minute; centrifuge at 3200 rpm for 5 minutes; (Sample Pretreatment: Homogenize 10 gm beef kidney and spike with pesticides at 50 ng/g.)
clean-up tube: Supel QuE Z-Sep+ tube (55296-U)
clean-up process: transfer 3 mL of the acetonitrile layer into a Supel QuE Z-Sep+ cleanup tube (55296-U); shake for 1 minute; centrifuge at 3400 rpm for 3 minutes; draw off supernatant for LVI-GCMS analysis
column: F.S. CAP. SLB-5MS 20 m x 0.18 mm I.D., 0.36 μm (28576-U)
oven: 70 °C ( 0.5 min), 25 °C/min to 125 °C, 10 °C/min to 200 °C, 5 °C/min to 300 °C/min (1 min)
inj. temp.: programmed, 60 °C (0.28 min), 600 °C/min to 325 °C (5 min)
detector: MSD
MSD interface: 325 °C
carrier gas: helium, 1 mL/min constant flow
injection: 10 μL LVI, PTV solvent vent, rapid injection speed
liner: 4 mm ID FocusLiner with taper
sample: Beef Kidney extract

Eignung

application for SPE

Anwendung(en)

food and beverages

Hinweis zur Analyse

Beef kidney was analyzed for pesticides by GC/MS-SIM after extraction and cleanup. Dispersive SPE was used for both extraction and cleanup. Since beef kideny contains approximately 5% fat, Z-Sep + was used for cleanup.

Rechtliche Hinweise

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany
Supel is a trademark of Sigma-Aldrich Co. LLC

Analyt

Beschreibung

    Diphenylamine
    Hexachlorobenzene
    Lindane
    Endosulfan I
    4,4′-DDE
    1,1-Dichloro-2,2-bis(4-chlorophenyl)ethane
    Endosulfan sulfate
    4,4′-DDT
    Piperonylbutoxide
    Bifenthrin
    Permethrin (isomers) solution
    Alle anzeigen (11)

SPE-Röhrchen oder -Platte

Produkt-Nr.
Beschreibung
Preisangaben

Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Leider sind derzeit keine COAs für dieses Produkt online verfügbar.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.