Direkt zum Inhalt
Merck

M9671

Sigma-Aldrich

(±)-2-Methyl-2,4-pentandiol

BioXtra, ≥99% (GC)

Synonym(e):

Hexylenglykol, MPD

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
CH3CH(OH)CH2C(CH3)2OH
CAS-Nummer:
Molekulargewicht:
118.17
Beilstein:
1098298
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12352100
PubChem Substanz-ID:
NACRES:
NA.26

Dampfdichte

4.1 (vs air)

Dampfdruck

0.02 mmHg ( 20 °C)

Produktlinie

BioXtra

Assay

≥99% (GC)

Form

liquid (or viscous liquid)

Expl.-Gr.

7.4 %

Verunreinigungen

≤0.0005% Phosphorus (P)

Glührückstand

≤0.1%

Brechungsindex

n20/D 1.427 (lit.)

bp

197 °C (lit.)

mp (Schmelzpunkt)

−40 °C (lit.)

Dichte

0.925 g/mL at 25 °C (lit.)

Anionenspuren

chloride (Cl-): ≤0.05%
sulfate (SO42-): ≤0.05%

Kationenspuren

Al: ≤0.0005%
Ca: ≤0.0005%
Cu: ≤0.0005%
Fe: ≤0.0005%
K: ≤0.005%
Mg: ≤0.0005%
NH4+: ≤0.05%
Na: ≤0.005%
Pb: ≤0.001%
Zn: ≤0.0005%

SMILES String

CC(O)CC(C)(C)O

InChI

1S/C6H14O2/c1-5(7)4-6(2,3)8/h5,7-8H,4H2,1-3H3

InChIKey

SVTBMSDMJJWYQN-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Piktogramme

Health hazardExclamation mark

Signalwort

Warning

Gefahreneinstufungen

Eye Irrit. 2 - Repr. 2 - Skin Irrit. 2

Lagerklassenschlüssel

10 - Combustible liquids

WGK

WGK 1

Flammpunkt (°F)

201.2 °F - closed cup

Flammpunkt (°C)

94 °C - closed cup

Persönliche Schutzausrüstung

Eyeshields, Gloves, type ABEK (EN14387) respirator filter


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Jose Antonio Cuesta-Seijo et al.
Structure (London, England : 1993), 18(9), 1210-1219 (2010-09-10)
Enzymatic reactions involving bilayer lipids occur in an environment with strict physical and topological constraints. The integral membrane enzyme PagP transfers a palmitoyl group from a phospholipid to lipid A in order to assist Escherichia coli in evading host immune
Yoshikazu Tanaka et al.
Protein science : a publication of the Protein Society, 20(2), 448-456 (2011-02-01)
Staphylococcal α-hemolysin is expressed as a water-soluble monomeric protein and assembles on membranes to form a heptameric pore structure. The heptameric pore structure of α-hemolysin can be prepared from monomer in vitro only in the presence of deoxycholate detergent micelles
Catherine Michaux et al.
Journal of molecular biology, 375(5), 1477-1488 (2007-12-18)
Sodium dodecyl sulfate (SDS) is a highly effective and widely used protein denaturant. We show that certain amphipathic cosolvents such as 2-methyl-2,4-pentanediol (MPD) can protect proteins from SDS denaturation, and in several cases can refold proteins from the SDS-denatured state.
Ami Matsumoto et al.
Acta crystallographica. Section F, Structural biology and crystallization communications, 69(Pt 3), 332-335 (2013-03-23)
Peptidyl-tRNA is produced from the ribosome as a result of aborted translation. Peptidyl-tRNA hydrolase cleaves the ester bond between the peptide and the tRNA of peptidyl-tRNA molecules, to recycle tRNA for further rounds of protein synthesis. In this study, peptidyl-tRNA
Armando G Villaseñor et al.
Acta crystallographica. Section D, Biological crystallography, 68(Pt 8), 893-900 (2012-08-08)
Focused acoustic energy allows accurate and precise liquid transfer on scales from picolitre to microlitre volumes. This technology was applied in protein crystallization, successfully transferring a diverse set of proteins as well as hundreds of precipitant solutions from custom and

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.