GE38152103011150
Sera-Mag™ Magnetic Oligo(dt) particles
Cytiva 38152103011150, 1 μm avg. part. size, suspension (1% Solids)
Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise
Alle Fotos(1)
About This Item
Empfohlene Produkte
ligand
(carboxylate modified particles)
Form
suspension (1% Solids)
Verpackung
pkg of 1 mL
Hersteller/Markenname
Cytiva 38152103011150
Konzentration
10 mg/mL
Durchschnittliche Teilgröße
1 μm
Versandbedingung
wet ice
Lagertemp.
2-8°C
Verwandte Kategorien
Allgemeine Beschreibung
Sera-Mag™ SpeedBeads and Sera-Mag™ Carboxylate-Modified Magnetic Particles combine a fast magnetic response time and high binding capacity with a large surface area, high sensitivity, stability, physical integrity, and fast reaction kinetics. Covalent coupling of biomolecules such as proteins and nucleic acids to carboxyl groups on the surface is easily accomplished using our standard coupling technology. The core of the particle is made by a free radical emulsion polymerization of styrene and acid monomer. One (Sera-Mag™) or two (Sera-Mag™ SpeedBeads) layers of magnetite are then coated onto this core, while the surface is modified to minimize non-specific binding of proteins.
Anwendung
Sera-Mag™ SpeedBeads and Sera-Mag™ Carboxylate-Modified Magnetic Particles typical application uses include sample preparation, proteomics, nucleic acid isolation, and immunoassay applications.
Sera-Mag™ Magnetic Olido(dt) particles can be used for convenient isolation and extraction of mRNA from a variety of sources for downstream applications such as RT-PCR, cDNA library construction, cDNA microarrays, affinity purification, primer extension and subtractive hybridization.
Sera-Mag™ Magnetic Olido(dt) particles can be used for convenient isolation and extraction of mRNA from a variety of sources for downstream applications such as RT-PCR, cDNA library construction, cDNA microarrays, affinity purification, primer extension and subtractive hybridization.
Sera-Mag™ SpeedBeads and Sera-Mag™ Carboxylate-Modified Magnetic Particles typical application uses include sample preparation, proteomics, nucleic acid isolation, and immunoassay applications.
Leistungsmerkmale und Vorteile
Sera-Mag™ SpeedBeads and Sera-Mag™ Carboxylate-Modified Magnetic Particles allow convenient covalent coupling of target molecules.
- Carboxylic groups on the surface permit easy covalent coupling to biomolecules of interest using convenient carbodiimide chemistry.
- Different levels of hydrophobicity/hydrophilicity available.
- Available in Sera-Mag™ SpeedBeads and original Sera-Mag™ versions.
- Excellent sensitivity and low nonspecific binding for greater accuracy.
- Fast Magnetic Response Times and Stable Physical Integrity.
- Very high, specific poly A+ binding capacity ensures maximum extraction of mRNA.
- Covalently bound oligo(dT)14 prevents leaching from the particle surface.
- Encapsulation means no exposed iron and minimized interference with downstream enzymatic applications.
- Uniform, nominal 1 μm diameter provides high surface area and excellent lot-to-lot reproducibility.
Sera-Mag™ SpeedBeads and Sera-Mag™ Carboxylate-Modified Magnetic Particles allow convenient covalent coupling of target molecules.
- Carboxylic groups on the surface permit easy covalent coupling to biomolecules of interest using convenient carbodiimide chemistry.
- Different levels of hydrophobicity/hydrophilicity available.
- Available in Sera-Mag™ SpeedBeads and original Sera-Mag™ versions.
- Excellent sensitivity and low nonspecific binding for greater accuracy.
- Fast Magnetic Response Times and Stable Physical Integrity
Lagerung und Haltbarkeit
Unless otherwise stated, refrigerate (2-8 °C) product when not in use but do not freeze. Store upright and keep bottle tightly sealed. Mix product with gentle inversion by hand, roller or vortex mixer.
Hinweis zur Analyse
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
Rechtliche Hinweise
Sera-Mag is a trademark of Cytiva
Lagerklassenschlüssel
12 - Non Combustible Liquids
WGK
WGK 3
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Computational identification and systematic classification of novel cytochrome P450 genes in Salvia miltiorrhiza.
PLoS ONE, 9(12), e115149-e115149 (2014)
Sequencing, Annotation, and Characterization of the Influenza Ferret Infectome.
Journal of Virology, 87(4), 1957-1966 (2013)
De novo transcriptome assembly of the mountain fly Drosophila nigrosparsa using short RNA-seq reads.
Molecular Ecology Resources null
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.