Direkt zum Inhalt
Merck
Alle Fotos(1)

Dokumente

KEGBG050HH

Millipore

Millipore Express® SPG 0,2 µm, Opticap® XL Kapsel

non-sterile, pore size 0.2 μm

Synonym(e):

Gamma Phobic Opticap® XL 50 Express SPG 0.2 HB/HB

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806
eCl@ss:
32031690
NACRES:
NB.24

Materialien

PBT-based blend (gamma-stable)
polyethersulfone membrane

Qualitätsniveau

Sterilität

irradiated
non-sterile

Kompatibilität mit Sterilisationsverfahren

gamma compatible

Leistungsmerkmale

hydrophobic

Hersteller/Markenname

Opticap®

Parameter

2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
4.1 bar max. inlet pressure (60 psi) at 23 °C
4.2 bar max. differential pressure (60 psid) at 25 °C (Forward)

Methode(n)

gas filtration: suitable

Länge

7.2 cm (2.84 in.)

Breite

2.4 in.

Durchmesser

6.2 cm (2.4 in.)

Filtrationsfläche

19.6 cm2

Verunreinigungen

≤0.25 EU/mL (LAL test, Aqueous extraction)

Gravimetrisch bestimmte extrahierbare Substanzen

≤1.0 mg

Matrix

Millipore Express® SPG

Porengröße

0.2 μm pore size

Blasenpunkt

≥1170 mbar (17 psig), air with 100% IPA at 23 °C

Fitting

inlet stepped hose barb for 6.5-9.5 mm I.D. silicone flexible tubing
outlet hose barb
outlet stepped hose barb for 6.5-9.5 mm I.D. silicone flexible tubing
female Luer slip interior
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)

Verwandte Kategorien

Angaben zur Herstellung

Sterilization Method
Gamma compatible to 45 kGy; OR 3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable

Hinweis zur Analyse

HydroCorr: ≤0.03 mL/min @ 2.6 bar (38 psig)
Bacterial Retention
Quantitative retention of 107 CFU/cm2Brevundimonas diminuta (ATCC® 19146) per ASTM methodology
Gravimetric Extractables: in 70/30 % IPA/water

Sonstige Hinweise

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Rechtliche Hinweise

ATCC is a registered trademark of American Type Culture Collection
Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.