HADCYMAG-61K
MILLIPLEX® Human Adipocyte Magnetic Bead Panel - Endocrine Multiplex Assay
The Human Adipocyte Magnetic Bead Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 11 Adipocyte protein biomarkers in cell culture samples.
About This Item
Empfohlene Produkte
Qualitätsniveau
Speziesreaktivität
human
Hersteller/Markenname
Milliplex®
assay range
accuracy: 100%
(IL-6)
accuracy: 102%
(TNFα)
accuracy: 103%
(MCP-1)
accuracy: 83%
(PAI-1 (total))
accuracy: 99%
(HGF)
sensitivity: 0.2 pg/mL
(MinDC+2SD; IL-8)
sensitivity: 0.2 pg/mL
(MinDC+2SD; NGF)
sensitivity: 0.2 pg/mL
(MinDC+2SD; TNF?)
sensitivity: 0.6 pg/mL
(MinDC+2SD; IL-6)
sensitivity: 10 pg/mL
(MinDC+2SD; Leptin)
sensitivity: 15 pg/mL
(MinDC+2SD; Adiponectin)
sensitivity: 2.0 pg/mL
(MinDC+2SD; IL-1?)
sensitivity: 2.1 pg/mL
(MinDC+2SD; MCP-1)
sensitivity: 3.0 pg/mL
(MinDC+2SD; HGF)
sensitivity: 4.4 pg/mL
(MinDC+2SD; Resistin)
sensitivity: 4.6 pg/mL
(MinDC+2SD; PAI-1 (total))
standard curve range: 0.29-4,000 pg/mL
(IL-8)
standard curve range: 0.32-5,000 pg/mL
(NGF)
standard curve range: 0.38-6,000 pg/mL
(TNFα)
standard curve range: 0.51-8,000 pg/mL
(IL-1β)
standard curve range: 0.96-150,000 pg/mL
(IL-6)
standard curve range: 0.96-150,000 pg/mL
(MCP-1)
standard curve range: 26-400,000 pg/mL
(Adipnectin)
standard curve range: 6.4-100,000 pg/mL
(HGF)
standard curve range: 6.4-100,000 pg/mL
(Resistin)
standard curve range: 9.6-150,000 pg/mL
(Leptin)
standard curve range: 9.6-150,000 pg/mL
(PAI-1)
inter-assay cv: <15%
intra-assay cv: <10%
(Adiponectin)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-8)
inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1)
inter-assay cv: <15%
intra-assay cv: <10%
(Resistin)
inter-assay cv: <20%
intra-assay cv: <10%
(HGF)
inter-assay cv: <20%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <20%
intra-assay cv: <10%
(NGF)
inter-assay cv: <20%
intra-assay cv: <10%
(PAI-1 (total))
inter-assay cv: <20%
intra-assay cv: <10%
(TNFα)
inter-assay cv: <20%
intra-assay cv: <15%
(IL-1β)
inter-assay cv: <25%
intra-assay cv: <20%
(Leptin)
Methode(n)
multiplexing: suitable
Nachweisverfahren
fluorometric (Luminex xMAP)
Versandbedingung
wet ice
Allgemeine Beschreibung
The MILLIPLEX® Human Adipocyte Panel is an 11-plex kit to be used for the simultaneous quantification of any or all of the following analytes in cell/tissue culture samples: Adiponectin, HGF, IL-β, IL-6, IL-8, Leptin, MCP-1, NGF, PAI-1 (total), Resistin, TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
Spezifität
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Anwendung
- Analytes: Adiponectin, HGF, IL-1β, IL-6, IL-8, Leptin, MCP-1, NGF, PAI-1 (Total), Resistin, TNF-α
- Recommended Sample Type: Tissue/cell culture supernatants or extracts
- Recommended Sample Dilution: 25 μL per well of undiluted tissue/cell culture sample; samples may require dilution with an appropriate medium prior to assay
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Endocrine
Leistungsmerkmale und Vorteile
Verpackung
Lagerung und Haltbarkeit
Sonstige Hinweise
Rechtliche Hinweise
Haftungsausschluss
Signalwort
Danger
H-Sätze
Gefahreneinstufungen
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Lagerklassenschlüssel
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Verwandter Inhalt
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.