SeQuant ZIC®-cHILIC 100Å (3 µm) HPLC Columns

L x I.D. 50 mm x 2.1 mm HPLC Column, PEEK-lined stainless steel

Synonym(e):

Zwitterionic Hydrophilic Interaction Liquid Chromatography HPLC Column

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41115709
NACRES:
SB.52

product name

SeQuant ZIC®-cHILIC, 3µm, 100Å, 150 x 4.6 mm, PEEK-lined stainless steel column, suitable for HPLC

Materialien

PEEK-lined stainless steel column

Qualitätsniveau

Agentur

suitable for USP L114

Produktlinie

SeQuant

Leistungsmerkmale

endcapped: no

Parameter

500 bar pressure
70 °C max. temp.

Methode(n)

HPLC: suitable
LC/MS: suitable
mass spectrometry (MS): suitable (High)

Säule L × ID

15 cm × 4.6 mm

Matrix

fully porous particle

Aktive Matrixgruppe

ZIC-HILIC bonding phase

Partikelgröße

3 μm

Porengröße

100 Å pore size

Betriebs-pH-Wert

2-7.5

Trenntechnik

hydrophilic interaction (HILIC)

Lagertemp.

no temp limit

Allgemeine Beschreibung

SeQuant ZIC®-HILIC Columns are designed to retain and separate all types of polar and hydrophilic compounds and for robust chromatography with high selectivity and reproducibility. The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.The Pore size of 100 Å makes this column perfectly suitable for the separation of small polar molecules under HILIC conditions.The column dimension of 150 mm length x 4.6 mm ID is the best choice for the separation of polar compounds using a standard HPLC Instrument.Thanks to their favorable retention and robust performance, SeQuant HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant ZIC®-HILIC for analysis of melamine and related substances. SeQuant HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.Learn more about the Supelco HPLC Column portfolio and Method development:Brochure: HPLC and UHPLC Column Selection Guide Brochure: A Practical Guide to HPLC - Method Development Guide

Hinweis zur Analyse

Druck: ≤ 50 bar
Theoretische Bodenzahl (N/m) (Cytosine): ≥ 90000
Symmetrie (Cytosine): 0.95 - 1.25

Rechtliche Hinweise

SeQuant is a trademark of Merck KGaA, Darmstadt, Germany
ZIC is a registered trademark of Merck KGaA, Darmstadt, Germany

Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.