736171

Supelco

1,4-Dioxan -Lösung

NMR reference standard, 40% in benzene-d6 (99.6 atom % D), NMR tube size 5 mm × 8 in.

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
C4H8O2
CAS-Nummer:
Molekulargewicht:
88.11
MDL-Nummer:
UNSPSC-Code:
12142201
PubChem Substanz-ID:
NACRES:
NA.24

Qualität

NMR reference standard
analytical standard

Konzentration

40% in benzene-d6 (99.6 atom % D)

Methode(n)

NMR: suitable

NMR-Röhrchengröße

5 mm × 8 in.

NMR-Röhrchenwandstärke

0.24 mm , ultra-thin wall

Eignung

suitable for NMR (reference standard)

Format

single component solution

SMILES String

C1COCCO1

InChI

1S/C4H8O2/c1-2-6-4-3-5-1/h1-4H2

InChIKey

RYHBNJHYFVUHQT-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Leistungsmerkmale und Vorteile

13C PW90 Empfindlichkeit

Menge

5 mm O.D. tube contains 0.700 mL.

Signalwort

Danger

Gefahreneinstufungen

Aquatic Chronic 3 - Asp. Tox. 1 - Carc. 1A - Eye Irrit. 2 - Flam. Liq. 2 - Muta. 1B - Skin Irrit. 2 - STOT RE 1 - STOT SE 3

Zielorgane

Blood, Respiratory system

Zusätzliche Gefahrenhinweise

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 3

Flammpunkt (°F)

53.6 °F - closed cup

Flammpunkt (°C)

12 °C - closed cup


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Daniel Gerrity et al.
Water research, 46(19), 6257-6272 (2012-10-16)
The performance of ozonation in wastewater depends on water quality and the ability to form hydroxyl radicals (·OH) to meet disinfection or contaminant transformation objectives. Since there are no on-line methods to assess ozone and ·OH exposure in wastewater, many
Venkateshwarlu Gurram et al.
Chemistry, an Asian journal, 7(8), 1853-1861 (2012-05-10)
Reaction conditions for the CC cross-coupling of O(6)-alkyl-2-bromo- and 2-chloroinosine derivatives with aryl-, hetaryl-, and alkylboronic acids were studied. Optimization experiments with silyl-protected 2-bromo-O(6)-methylinosine led to the identification of [PdCl(2)(dcpf)]/K(3)PO(4) in 1,4-dioxane as the best conditions for these reactions (dcpf=1,1'-bis(dicyclohexylphosphino)ferrocene).
A Pan et al.
Langmuir : the ACS journal of surfaces and colloids, 28(39), 13830-13843 (2012-09-07)
Mixed aquo-organic solvents are used in chemical, industrial, and pharmaceutical processes along with amphiphilic materials. Their fundamental studies with reference to bulk and interfacial phenomena are thus considered to be important, but such detailed studies are limited. In this work
Naoyuki Kishimoto et al.
Water research, 47(5), 1919-1927 (2013-02-09)
This paper reports on the reusability and the optimal reuse of iron-rich sludge for an electrochemical Fenton-type process using sequencing batch mode and separation batch mode reuse models. In the sequencing batch mode, processes of electrochemical treatment, neutralization, sedimentation, and
Sheau-Yun Dora Chiang et al.
Journal of environmental monitoring : JEM, 14(9), 2317-2326 (2012-07-25)
An intrinsic biodegradation study involving the design and implementation of innovative environmental diagnostic tools was conducted to evaluate whether monitored natural attenuation (MNA) could be considered as part of the remedial strategy to treat an aerobic aquifer contaminated with 1,4-dioxane

Artikel

Sigma-Aldrich.com provides an informational article regarding the use of stable, labeled isotopes as NMR reference standards.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.