G005816
GC Analysis of Sterols (Silylated Derivatives) in Olive Oil (Free Sterol Fraction) on SLB®-5ms after SPE using Discovery DSC-Si
suitable for GC, application for SPE
About This Item
Technique(s)
gas chromatography (GC): suitable
solid phase extraction (SPE): suitable
Paramètres du test
sample preparation: SPE (Solid Phase Extraction)
sample/matrix: olive oil spiked with a mixed sterol standard at 5 μg/g
SPE tube/cartridge: Discovery DSC-Si, 1 g/6 mL (52656-U)
condition: 2 x 5 mL hexane
sample addition: 1 mL
elution: esters fraction: 2.5 mL of hexane:ethyl acetate (90:10); free sterols fraction; 5 mL of hexane:ethyl acetate (90:10) and 3 mL x 5 of ethanol:diethyl ether:hexane (50:25:25)
eluate post-treatment: Evaporate to dryness and perform silylation as described in the Analysis Note.
column: SLB-5ms, 20 m x 0.20 mm I.D., 0.20 μm (28564-U)
oven: 125 °C (1 min), 10 °C/min to 325 °C (10 min)
inj. temp.: 250 °C
detector: MSD, rn/z 500 - 600
MSD interface: 325 °C
carrier gas: helium, 0.6 mL/min, constant
injection: 1 μL, splitless
liner: 4 mm I.D. single taper
sample: Olive oil sample; fractionated, transesterified, and silylated
Adéquation
application for SPE
Application(s)
agriculture
food and beverages
Remarque sur l'analyse
Weigh 0.25 gm oil into test tube. For spiked sample add 12.5 μL of 65-100 μg/mL mixed sterol std. Add 1 ml of hexane:ethyl acetate (90:10). After SPE fractionation, evaporate solvent from each fraction, add 1 ml of 30% methanolic sodium methoxide:MeOH:MTBE solution (13:27:60), mix and let sit at room temp for 30 min. Add 1 ml of water and 2 mL of n-heptane. Withdraw aqueous phase (bottom) and replace w/ 1 mL of 1% citric acid solution. Withdraw organic phase and dry over anhydrous sodium sulfate. Silylation: Evaporate organic phase to dryness. Add 125 μL of Sylon BFT and 125 μL of pyridine. Heat at 70°C for 20 min. The sample is then ready for GC-MS analysis.
Informations légales
Analyte
Colonne analytique
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
Désolés, nous n'avons pas de COA pour ce produit disponible en ligne pour le moment.
Si vous avez besoin d'assistance, veuillez contacter Service Clients
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique