Accéder au contenu
MilliporeSigma
Toutes les photos(15)

Key Documents

ZRB1177

Sigma-Aldrich

Anti-Iba1/AIF1 Antibody, clone 16B14, ZooMAb® Rabbit Monoclonal

enhanced validation
greener alternative

recombinant, expressed in HEK 293 cells

Synonyme(s) :

Anti-AIF-1, Anti-IBA1, Anti-IRT-1, Anti-IRT1

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12352203
Nomenclature NACRES :
NA.43

Source biologique

rabbit (recombinant)

Niveau de qualité

Produit recombinant

expressed in HEK 293 cells

Conjugué

unconjugated

Forme d'anticorps

purified antibody

Type de produit anticorps

primary antibodies

Clone

16B14, recombinant monoclonal

Gamme de produits

ZooMAb® learn more

Forme

lyophilized

Poids mol.

calculated mol wt 16.70 kDa
observed mol wt ~16 kDa

Espèces réactives

human, mouse

Conditionnement

antibody small pack of 25 μL

Caractéristiques du produit alternatif plus écologique

Waste Prevention
Designing Safer Chemicals
Design for Energy Efficiency
Learn more about the Principles of Green Chemistry.

Validation améliorée

recombinant expression
Learn more about Antibody Enhanced Validation

sustainability

Greener Alternative Product

Technique(s)

immunofluorescence: suitable
immunohistochemistry (formalin-fixed, paraffin-embedded sections): suitable
western blot: suitable (peptide)

Isotype

IgG

Numéro d'accès UniProt

Autre catégorie plus écologique

Conditions d'expédition

ambient

Température de stockage

2-8°C

Modification post-traductionnelle de la cible

unmodified

Informations sur le gène

human ... AIF1(199)

Description générale

We are committed to bringing you greener alternative products, which adhere to one or more of The 12 Principles of Green Chemistry.This antibody is Preservative-free, produced without the harm or sacrifice of animals and exceptionally stable to allow for ambient shipping and storage if needed and thus aligns with "Waste Prevention", "Designing Safer Chemicals" and "Design for Energy Efficiency". Click here for more information.
ZooMAb antibodies represent an entirely new generation of recombinant monoclonal antibodies.

Each ZooMAb antibody is manufactured using our proprietary recombinant expression system, purified to homogeneity, and precisely dispensed to produce robust and highly reproducible lot-to-lot consistency. Only top-performing clones are released for use by researchers. Each antibody is validated for high specificity and affinity across multiple applications, including its most commonly used application. ZooMAb antibodies are reliably available and ready to ship when you need them.

Learn more about ZooMAb here.

Spécificité

Clone 16B14 is a ZooMAb rabbit recombinant monoclonal antibody that specifically detects Allograft inflammatory factor 1 (AIF1). It targets an epitope within 21 amino acids from the C-terminal region.

Immunogène

KLH-conjugated linear peptide corresponding to 21 amino acids from the C-terminal region of human Allograft inflammatory factor 1 (AIF1).

Application

Anti-Iba1/AIF1, clone 16B14 ZooMAb, Cat. No. ZRB1177, is a highly specific recombinant rabbit monoclonal antibody that detects Iba1/AIF1 and has been tested for use in Immunofluorescence, Immunohistochemistry (Paraffin), and Western Blotting.
Western Blotting Analysis: A 1:1,000 dilution from a representative lot detected Iba1/AIF1 in mouse and human brain tissue lysate.

Immunohistochemistry (Paraffin) Analysis: A 1:100 dilution from a representative lot detected Iba1/AIF1 in human bone marrow & human cerebral cortex tissue sections.

Immunofluorescence Analysis: A 1:100 dilution from a representative lot detected Iba1/AIF1 in human cerebral cortex tissue sections.

Note: Actual optimal working dilutions must be determined by the end user as specimens and experimental conditions may vary.

Description de la cible

Allograft inflammatory factor 1 (UniProt: P55008; also known as AIF1, Ionized calcium-binding adapter molecule 1, Protein G1) is encoded by the AIF1 (also known as G1, IBA1) gene (Gene ID: 199) in human. AIF1/IBA1 is a highly conserved cytoplasmic, calcium binding, inflammation responsive scaffold protein that is detected in T-lymphocytes and peripheral blood mononuclear cells. It has also been shown to associate with the actin cytoskeleton at membrane ruffles and at sites of phagocytosis. It is not present in normal arteries, but its expression is induced in vascular smooth muscle cells in response to arterial injury where it enhances growth and promote proliferation in vascular smooth muscle cells through deregulation of the cell cycle by shortening the cell cycle and altering the expression of cyclins. AIF1 is also found in activated macrophages where its expression is augmented by cytokines, particularly interferon gamma. It is also considered as a marker for activated macrophages. Serum AIF-1 levels have been correlated with albuminuria and eGFR in type 2 diabetic subjects and serves as a marker for diabetic nephropathy. Three isoforms of AIF1/IBA1 have been described that are produced by alternative splicing. This clone will react with isoforms 1 and 2 that contain this immunogen sequence. This ZooMAb recombinant monoclonal antibody, generated by our propriety technology, offers significantly enhanced specificity, affinity, reproducibility, and stability over conventional monoclonals. Fukui, M., et al. (2012). Diabetes Res. Clin. Pract. 98(1); 146-150; Autieri, MV., and Carbone, CM (2001). Arterioscler. Thromb. Vasc. Biol. 21(9);1421-1426.

Forme physique

Purified recombinant rabbit monoclonal antibody IgG, lyophilized in PBS with 5% Trehalose. Normal appearance is a coarse or translucent resin. Contains no biocide or preservatives, such as azide, or any animal by-products. Larger pack sizes provided as multiples of 25 μL.

Reconstitution

300 μg/mL after reconstitution at 25 μL. Please refer to guidance on suggested starting dilutions and/or titers per application and sample type.

Stockage et stabilité

Recommend storage of lyophilized product at 2-8°C; Before reconstitution, micro-centrifuge vials briefly to spin down material to bottom of the vial; Reconstitute each vial by adding 25 μL of filtered lab grade water or PBS; Reconstituted antibodies can be stored at 2-8°C, or -20°C for long term storage. Avoid repeated freeze-thaws.

Informations légales

ZooMAb is a registered trademark of Merck KGaA, Darmstadt, Germany

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Vous ne trouvez pas le bon produit ?  

Essayez notre Outil de sélection de produits.

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Sang Heon Lee et al.
Advanced functional materials, 32(25) (2022-11-17)
The Utah array powers cutting-edge projects for restoration of neurological function, such as BrainGate, but the underlying electrode technology has itself advanced little in the last three decades. Here, advanced dual-side lithographic microfabrication processes is exploited to demonstrate a 1024-channel

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique